Questions and Answers

  • T
    teresa70Sep 4, 2025
    Why does CoolSpace Freezer breaker trip when switch is turned on?
    • F
      frankrobertsSep 4, 2025
      If the breaker trips or the fuse blows when you turn on the switch of your CoolSpace Freezer, check the power cord length and breaker rating. Also, check for a locked-up pump. Refer to page 2 for unit amperage draw and to determine the required cord gauge. You might also need to replace the pump.
  • B
    Brenda WheelerSep 18, 2025
    What to do if CoolSpace Glacier CS5-18-VD Freezer pump motor will not run when switch is turned on?
    • C
      campbellkevinSep 18, 2025
      If the pump motor of your CoolSpace Freezer will not run when the switch is turned on, and if the fan doesn’t start, check the breaker and cord plug-in. If the fan does start, check for power to and through the pump switch when turned on. Also, fill the water reservoir.
  • H
    hsmithSep 16, 2025
    Why CoolSpace Freezer fan motor won’t run and makes a humming sound?
    • C
      Cheryl JonesSep 16, 2025
      If the fan motor of your CoolSpace Freezer won’t run and makes a humming sound, the blade might be in contact with the shroud, or the motor might be stalled. Re-center the blade hub and replace the motor.
  • P
    Patricia SalasSep 14, 2025
    Why CoolSpace Glacier CS5-18-VD Freezer pump won’t run and power is available?
    • J
      Jenny RodriguezSep 14, 2025
      If the pump of your CoolSpace Freezer won’t run and power is available, ensure the switch is working. Also, check if the water level is high enough to activate the low-water cut-off circuit. Replace the switch if it's not completing the circuit and fill the water reservoir enough to activate the Low Water Shut-off switch.
  • B
    Brian BoyleSep 12, 2025
    How to fix too many dry streaks in the CoolSpace Glacier CS5-18-VD Freezer pads?
    • L
      Lisa ClarkSep 13, 2025
      If you observe too many dry streaks in the pads of your CoolSpace Freezer, the holes in the spray bar might be blocked, or the water flow might need adjustment. Remove the spray bar, remove the plug, and clean the tube and holes. Then, open the water flow control valve.
  • K
    Kimberly PayneSep 12, 2025
    Why is water leaking from CoolSpace Glacier CS5-18-VD water flow control valve?
    • P
      Paula MartinSep 12, 2025
      If water is leaking from the water flow control valve of your CoolSpace Freezer, the washer or stem might be worn, or the jam nut or lock nut might be loose. Replace the water flow control valve and tighten the jam nut.
  • A
    Angela RoweSep 9, 2025
    Why CoolSpace Freezer fan will not reach speed but turns and makes humming sound?
    • A
      Angela Obrien DVMSep 9, 2025
      If the fan of your CoolSpace Freezer will not reach full speed but turns and makes a humming sound, check the capacitor (where visible) and motor electrical connections. The extension cord might also be too small. Replace the capacitor or motor, and increase the cord gauge.
  • S
    Susan ConwaySep 7, 2025
    Why is water leaking from CoolSpace Glacier CS5-18-VD drain valve?
    • A
      anna43Sep 7, 2025
      If the water is leaking from the drain valve of your CoolSpace Freezer, it might be due to a worn washer or stem. Replace the washer, or replace the drain valve.
  • M
    Marco GreeneSep 5, 2025
    How to fix CoolSpace Glacier CS5-18-VD Freezer fan that won't run?
    • D
      donna14Sep 5, 2025
      If the fan of your CoolSpace Freezer won't run and makes no sound, reconnect the power or extension cord and reset the breaker.
  • J
    John MillerAug 21, 2025
    What to do if CoolSpace Glacier CS5-18-VD unit overflows?
    • D
      Diane HardyAug 21, 2025
      If the CoolSpace Freezer unit overflows from the reservoir or spits water through the fan, first, tighten the connections or replace the hose washers. If the issue persists, reduce water pressure by adding an inline reducer. Also, inspect all hoses for leaks.

Summary

Cool-Space Unit Setup

Operating Procedures

Starting the Pump and Adjusting Water Flow

Guides on flushing pads, filling the reservoir, turning on the fan, and adjusting water flow for optimal cooling.

Intuitive Control Panel Operation

Details the functions of the control panel buttons (Power, Fan, Pump, Mode, Timer) and indicators (Power, Low Water).

Maintenance and Storage

Troubleshooting and Repair

Troubleshooting Overview

Identifies the three main systems (fan, water, pump) and general approach to diagnosing problems.

Fan and Control Panel Troubleshooting

Lists common fan problems, their checks, solutions, and control panel error codes.

Water System Troubleshooting

Addresses common water system problems like leaks, overflows, and pad dryness, with checks and solutions.

Pump Troubleshooting

Identifies pump issues such as not running, humming, noise, or breaker trips, providing checks and solutions.

Repair Procedures

Warranty Information

CoolSpace Glacier CS5-18-VD Specifications

General IconGeneral
BrandCoolSpace
ModelGlacier CS5-18-VD
CategoryFreezer
LanguageEnglish

Related product manuals