EasyManua.ls Logo

Coolworks MWDCK-06CRN1-BK2 - User Manual

Coolworks MWDCK-06CRN1-BK2
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
WINDOW AIR CONDITIONER
s
Model: MWDCK-06CRN1-BK2; MWDCK-08CRN1-BK3
MWDCK-10CRN1-BK3; MWDCK-12CRN1-BK3
Question and Answer IconNeed help?

Do you have a question about the Coolworks MWDCK-06CRN1-BK2 and is the answer not in the manual?

Summary

Safety Precautions

General Safety Warnings

Essential warnings and cautions for safe operation and handling of the unit.

Safety Precautions

Additional Safety Cautions

Further safety measures for unit operation, cleaning, and environmental conditions.

Safety Precautions

Electrical Safety and Current Device Operation

Electrical safety, grounding, and testing the power supply cord's current detection device.

Operating Instructions

Understanding Normal Sounds

Explains common sounds produced by the air conditioner during operation.

Basic Air Conditioner Operation

Step-by-step guide to starting and operating the air conditioner for cooling.

Operating Instructions

Key Pad Features Overview

Introduces the unit's control panel buttons and their basic functions.

Operating Instructions

Detailed Control Panel Functions

Explains specific buttons like Fan Speed, Energy Saver, Sleep, Timer, and Filter check.

Operating Instructions

Display, Error Codes, and Vent Controls

Covers LED display, error codes, fresh air vent, and louver adjustments.

Installation Instructions

Preparation and Top Rail Installation

Details required tools, hardware, and the process for installing the top rail.

Installation Instructions

Installing Side Filler Panels

Guides on attaching and securing the side filler panels to the unit.

Installation Instructions

Unit Placement and Securing

Instructions for placing the unit, extending panels, and securing it.

Storm Window and Removal Procedures

Addresses storm window installation and unit removal steps.

Installation Instructions

Final Installation Steps and Removal Details

Covers sash lock, foam seal, and further removal instructions.

Care And Cleaning

Air Filter Cleaning

Instructions for checking, cleaning, and maintaining the air filter.

Cabinet Cleaning

Procedures for cleaning the unit's exterior cabinet.

Troubleshooting Tips

Common Problems and Solutions

Lists common issues with their corresponding solutions to save time and expense.

Remote Control Operating Instructions

Handling the Remote Control

Guidance on using the remote control and replacing batteries.

Remote Control Operating Instructions

Remote Control Specifications and Function Buttons

Details remote specifications and explains the function of each button.

Remote Control Operating Instructions

Operating Modes with Remote

How to use the remote for Auto, Cooling/Fan, and Dehumidifying operations.

Remote Control Operating Instructions

Sleep and Timer Operations

Instructions for activating Sleep mode and setting Auto Start/Stop timers.

Remote Control Operating Instructions

Combined Timer Functionality

Explains setting both ON and OFF timers simultaneously.

Air Conditioner Limited Warranty

Warranty Coverage and Consumer Responsibilities

Outlines the warranty period, what is covered, and consumer obligations.

Warranty Exclusions and Service Information

Details what is not covered by the warranty and how to obtain service.

Overview

This document is an instruction manual for a Cool Works window air conditioner, covering models MWDCK-06CRN1-BK2, MWDCK-08CRN1-BK3, MWDCK-10CRN1-BK3, and MWDCK-12CRN1-BK3. It provides comprehensive information on safety precautions, operating instructions, installation, care and cleaning, troubleshooting, remote control operation, and warranty details.

Function Description:

The Cool Works window air conditioner is designed to provide cooling and dehumidification for indoor spaces. It features multiple operating modes including Auto, Cool, Dry, and Fan Only, allowing users to select the most suitable setting for their comfort needs. The unit can also be used for room air circulation or to exhaust stale air in Fan Only mode. In Dry mode, it functions as a dehumidifier, reducing humidity in a closed space while providing some degree of cooling. The air conditioner includes an Energy Saver function, a Sleep mode for optimized night-time operation, and a Timer function for scheduled auto-start and auto-stop.

Important Technical Specifications:

The manual specifies operating temperature ranges for cooling:

  • Outdoor temperature: 18-43°C (64-109°F)
  • Indoor temperature: 17-32°C (62-90°F)
  • The relative humidity of the room should be less than 80% for optimal performance. If humidity exceeds 80%, condensed water may appear on the unit's surface.
  • The Cool circuit has an automatic 3-minute time-delayed start to prevent compressor overheating and circuit breaker tripping.
  • The control maintains any set temperature within 1°F/1°C.
  • The unit can display temperature in Fahrenheit or Celsius, switchable by pressing and holding the Left and Right Temp/Timer buttons simultaneously for 3 seconds.
  • The power supply cord includes a current detection device to reduce fire risk. If damaged, the cord must be replaced by the manufacturer or an authorized service center.
  • Installation requires a standard double-hung window with opening widths of 23 to 36 inches (584 mm to 914 mm). The vertical opening height (H) varies by model: 14 inches (356 mm) for 6000-8000 BTU/hr units and 15-1/2 inches (394 mm) for 10000-12000 BTU/hr units.
  • The unit must be properly grounded with a three-prong grounding plug.
  • The remote control (Model RG32A/E) operates on 3.0V (2 AAA batteries), with a lowest CPU emitting signal voltage of 2.4V and a signal receiving range of 16 ft (5 m). Its operating environment is -5°C to 60°C (23°F to 140°F).

Usage Features:

  • Control Panel and Remote Control: The unit can be controlled via its integrated keypad or a remote control.
  • Temperature Adjustment: Users can set the desired temperature between 62°F (17°C) and 86°F (30°C) using the UP/DOWN buttons. In Fan Only mode, the display shows the actual room temperature, and temperature cannot be adjusted.
  • Mode Selection: The Mode button cycles through Auto, Cool, Dry, and Fan modes.
  • Fan Speed: The Fan Speed button allows selection of Auto, Low, Med, or High fan speeds. In Dry mode, the fan speed is automatically controlled at a low speed. In Auto mode, fan speed is also automatically controlled.
  • Energy Saver: This function, available in Cool, Dry, and Auto modes, runs the fan for 3 minutes after the compressor shuts off, then cycles the fan on for 2 minutes at 10-minute intervals until the room temperature rises above the set temperature, restarting cooling.
  • Sleep Mode: In Cool, Heat (selected models only), or Auto mode, the selected temperature increases by 2°F/1°C after 30 minutes, and again after another 30 minutes. This new temperature is maintained for 6 hours before reverting to the original setting. Sleep mode can be canceled at any time.
  • Timer Function: Allows scheduling of auto-start and auto-stop programs up to 24 hours in advance, with 0.5-hour increments up to 10 hours, then 1-hour increments.
  • Fresh Air Vent Control (selected models): The vent can be set to recirculate indoor air (Vent Closed), draw fresh air into the room (Vent Open), or exchange air from the room while drawing fresh air in (Vent and Exhaust Open).
  • Air Directional Louvers: Horizontal louvers can be pivoted to direct airflow Up or Down, and levers moved side-to-side for Left/Right direction.
  • Current Device Test: The power supply cord has a TEST and RESET button to check the current detection device.

Maintenance Features:

  • Air Filter Cleaning: The air filter should be checked at least once a month. Trapped particles can cause frost accumulation on cooling coils. To clean, push the vent handle to closed, open the front panel, grasp the filter, and pull it out. Wash with liquid dishwashing detergent and warm water, rinse thoroughly, and dry completely. Alternatively, vacuum the filter. Do not use hot water over 40°C (104°F) or operate the unit without the filter.
  • Check Filter Reminder: An LED light illuminates after 250 hours of operation to remind users to clean the air filter. Press the Check Filter button to reset the light after cleaning.
  • Cabinet Cleaning: Unplug the unit before cleaning. Dust the cabinet and front with an oil-free cloth or wipe with a cloth dampened in warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. Avoid harsh cleaners, wax, or polish. Wring excess water from the cloth before wiping controls to prevent damage.
  • Winter Storage: If storing the unit for winter, remove it from the window according to installation instructions, cover it with plastic, and store it in its original carton.
  • Battery Replacement: The remote control uses two AAA batteries. Remove the cover, replace old batteries with new ones, ensuring correct polarity, and reattach the cover. Replacing batteries erases all programming, requiring reprogramming. Do not mix old and new batteries or different types. Dispose of used batteries in special containers.

Coolworks MWDCK-06CRN1-BK2 Specifications

General IconGeneral
BrandCoolworks
ModelMWDCK-06CRN1-BK2
CategoryAir Conditioner
LanguageEnglish