Revised: 02/12/2015 2/12/2015
1
CoonaraRoyal-Slimline,Classic
&Freestanding
Royal Slimline Royal Classic
CUSTOMER OPERATING INFORMATION
&
INSTALLATION INSTRUCTIONS
(For use with natural gas only)
Serial Number of Heater: ____________ Model: ___________________
Serial Number of Heater
: ____________
Model:
________________
Royal Slimline, Classic & Freestanding Gas Heaters
ARE AUSTRALIAN OWNED AND MANUFACTURED BY
SHAMIC SHEETMETAL
SHAMIC SHEETMETALSHAMIC SHEETMETAL
SHAMIC SHEETMETAL
(AUST.) PTY. LTD.
PO BOX 8, KILSYTH, VIC. 3137
PH: 03 9737 5300 FAX: 03 9761 6455
https://shamic.com
Royal Freestanding 1
Royal Freestanding 2

Questions and Answers

  • M
    madelinemurphyAug 15, 2025
    What to do if my Coonara Royal Slimline Indoor Fireplace fails to ignite?
    • E
      Elizabeth SanchezAug 15, 2025
      If your Coonara Indoor Fireplace fails to ignite or ignites and then goes out, several factors could be responsible. Check that the gas supply is connected and the pressure is adequate. Ensure the unit is plugged in and the switch is on, verifying the supply fuse. Point the remote at the bottom left-hand corner of the heater. Adjust the valve pressures. Wait at least 15 seconds between attempts to allow the unit to purge the combustion chamber. Check that all plugs inside the appliance are properly connected and located, and ensure the combustion fan and air pressure switch are operating correctly. Also, verify the correct orientation and connection of the active, neutral, and earth wires.
  • J
    Jill CummingsAug 18, 2025
    Why is there excessive carbon soot on my Coonara Royal Slimline Indoor Fireplace?
    • P
      Patricia ValenciaAug 18, 2025
      Excessive carbon (soot) deposits on the inside of your Coonara Indoor Fireplace's firebox, logs, or glass can be due to an incorrect gas type or pressure setting. To resolve this, ensure that the correct gas type, injector size, and pressure setting are used. Additionally, the primary air shutter may need adjustment to suit the gas type.
  • J
    John FordAug 21, 2025
    What to do if my Coonara Royal Slimline Indoor Fireplace unit fails to heat?
    • D
      Dawn StokesAug 21, 2025
      If your Coonara Indoor Fireplace unit fails to heat, refer to the troubleshooting steps for 'Room fan not operating'. Also, ensure that the correct gas type, injector size, and pressure setting are used. Check the injector, burner supply pipe, and valve for any foreign matter that may be causing a blockage.
  • H
    Heather RomeroAug 25, 2025
    What causes excessive flame height in a Coonara Indoor Fireplace?
    • K
      kristi98Aug 26, 2025
      Excessive flame height in your Coonara Indoor Fireplace is often caused by an incorrect gas type or pressure setting. Make sure you are using the correct gas type and that the injector size and pressure setting are accurate.
  • M
    Michael FranklinAug 28, 2025
    What to do if my Coonara Indoor Fireplace room fan is not operating?
    • V
      Victor ArellanoAug 28, 2025
      If the room fan in your Coonara Indoor Fireplace is not operating, note that the fan has a delayed start and will only begin once the unit warms up. Check the wiring to ensure it is properly connected. Make sure the fan is installed in the correct location. If the fan is blocked, remove it and clean it thoroughly.
  • D
    Daniel KimSep 1, 2025
    What to do if my Coonara Royal Slimline Indoor Fireplace burner will not spark?
    • E
      Evan GibsonSep 1, 2025
      If the burner on your Coonara Indoor Fireplace will not spark, the gap between the burner and sparker should be 3mm. To fix this, remove the front burner cover and use pliers to bend the tags holding the sparker. Be careful not to bend the sparker itself.
  • A
    Alan GrantSep 4, 2025
    What causes excessive flame lift off in my Coonara Royal Slimline Indoor Fireplace?
    • K
      Kent SwansonSep 4, 2025
      Excessive flame 'lift off' in your Coonara Indoor Fireplace can be caused by a flue or inlet blockage, or recirculation of flue gases. Clear any blockages. If the flue is incorrectly installed, it will need to be corrected.
  • A
    Arthur ConradSep 7, 2025
    Why does my Coonara Royal Slimline cut out and cycle on and off?
    • J
      jenniferbradleySep 7, 2025
      If your Coonara Indoor Fireplace cuts out after a period of time and then cycles on and off, refer to the troubleshooting steps for 'Room fan not operating'. Additionally, check for a heat exchanger blockage and clean it if necessary. Ensure that the correct gas type, injector size, and pressure setting are used.
  • J
    jim05Sep 12, 2025
    What to do if my Coonara Royal Slimline Indoor Fireplace will not operate on low?
    • R
      Ryan LawsonSep 12, 2025
      If your Coonara Indoor Fireplace will not operate on low, it could be due to an incorrect gas valve adjustment. Adjust the valve accordingly. Also, check the wiring to ensure it is correctly connected and not loose.

Summary

Warnings and Safety Precautions

Mandatory Operational Warnings

Critical instructions that must be followed to avoid voiding the warranty.

General Safety Guidelines

Key safety rules including warnings against improper operation and modifications.

Safety Guard Information

Details regarding the safety guard around the glass door and recommendation for a secondary guard.

Product Features and Operation

Product Features Overview

Highlights key features and specifications of the gas log heaters.

Pre-Operation Checks

Ensuring the flue terminal is clear and no combustible objects are near the unit before operation.

Operating the Heater

Steps for igniting the heater, heat settings, and fan operation.

Turning Appliance Off

Procedure for turning off the heater and fan behavior during cool-down.

Royal Inbuilt;Freestanding Operation

Specific operating sequence for inbuilt and freestanding models, including delays and heat settings.

Safety Features

Details on automatic pre-purge, automatic shut-off, and over-temperature protection.

Record Keeping

Section for recording purchase and installation details for convenience.

Installation Procedures

Installation Requirements

Mandatory installation by authorized technician and adherence to codes.

Installation Options Overview

Details on specific installation methods like zero clearance and flue kit usage.

Vertical Flue Installation

Instructions for connecting flue terminal to flexible pipes and sealing.

Rear Vent Flue Installation

Steps for installing rear vent flue for inbuilt and freestanding models.

Inbuilt Wall Cavity Installation

Procedures for inbuilt installation into stud wall cavities.

Inbuilt Weather Cover Installation

Steps for installing inbuilt heaters through walls with weather covers.

Technical Specifications and Maintenance

Appliance Dimensions

Physical dimensions for various Coonara models, including front, side, and rear views.

Pressure Adjustment

Instructions for adjusting gas outlet pressure for 843/845 models.

Wiring Diagram

Diagram illustrating wiring connections for thermostat, gas valve, and pressure switch.

Burner Removal

Step-by-step instructions for safely removing the burner assembly.

Log Set Installation

Guide for correct placement of ceramic logs on the ember bed.

Heater Care and Service

Advice on annual servicing, cleaning, and pre-service call checks.

Warranty and Troubleshooting

Warranty Claim Process

Steps for initiating and processing a warranty claim.

Warranty Details

Information on warranty coverage, periods, exclusions, and qualifications.

Troubleshooting Guide

Common problems, their possible causes, and recommended remedies.

Dimensions Overview

Dimensions Comparison

Comparative table of dimensions for different Coonara models.

Coonara Royal Slimline Specifications

General IconGeneral
TypeWood Heater
ConstructionSteel
Fuel TypeWood
Flue Size150mm
MaterialSteel
Warranty10 years firebox warranty