SP40S
Multi-Function Facility
Communication System
Installation, Testing,
Operation and
Maintenance Manual
Unless otherwise noted, SP40S refers to the SP40S family, consisting of
the SP40S, SP40SE, SP40S-D and SP40SE-D.
Part Number P84714 Revision M
Assembly Number A84715-001 Revision C
Copyright 2014 Cooper Wheelock, dba Cooper Notification. All Rights Reserved.

Table of Contents

Questions and Answers

  • G
    Gerald Conley DDSAug 21, 2025
    Why is there excessive noise from the speakers in my Cooper Notification SP40S?
    • J
      jasmine77Aug 21, 2025
      If you are experiencing excessive noise from the speakers of your Cooper Notification Conference System, ensure that the 4 metal standoffs are installed and securely fastened. Also, verify that the 4 screws are installed and securely fastened. The motherboard may not be properly grounded to the enclosure.
  • M
    mandersonSep 4, 2025
    What causes Strobe Notification Appliance Circuit to be open in Cooper Notification Conference System?
    • W
      William ThompsonSep 4, 2025
      If the Strobe Notification Appliance Circuit is open in your Cooper Notification Conference System, check for proper EOLR. Check the strobe notification appliance circuit wiring for an open condition.
  • J
    Jason WilliamsSep 2, 2025
    What to do if the Audio Notification Appliance Circuit is Open in Cooper Notification SP40S Conference System?
    • K
      Kyle GregorySep 3, 2025
      If the Audio Notification Appliance Circuit is Open in your Cooper Notification Conference System, check for proper EOLR. Also, check the speaker notification appliance circuit wiring for an open condition.
  • A
    Ashley McknightSep 1, 2025
    How do I troubleshoot Ground Fault Trouble on Cooper Notification SP40S?
    • A
      Andre KnightSep 1, 2025
      To troubleshoot a Ground Fault Trouble in your Cooper Notification Conference System, disconnect appliances from the strobe (TB12) and speaker (TB4) connections on the motherboard. Check the NAC circuits by checking for a resistance reading other than infinity between the appliance leads and the conduit.
  • M
    Mary WatersAug 30, 2025
    Why is the Digital Voice Signal too low or missing in my Cooper Notification SP40S Conference System?
    • K
      Kevin RiveraAug 31, 2025
      If the Digital Voice Signal is too low or missing in your Cooper Notification Conference System, check the memory chip (U31) to ensure it is installed properly. Verify that messages are recorded on the chip by activating them using the display buttons. Check the Digital Voice volume control (R73) for proper volume level. If the issue persists, consider replacing the motherboard.
  • J
    Jason JenkinsAug 29, 2025
    How to resolve Strobe Over current Protection being active on Cooper Notification SP40S?
    • B
      Brittany RussellAug 29, 2025
      If Strobe Over current Protection is active in your Cooper Notification Conference System, check the strobe output for excessive current calculation (2.0A for strobe circuit). If excessive current is calculated, remove appliances until the strobe current is below 2.0 Amps. If excessive current does not exist, and the strobe output is not operating, reset the SP40S by removing AC and battery power. Wait 30 seconds and reapply power. AC first and then batteries.
  • B
    beckerjoshuaAug 27, 2025
    What causes Audio Over current Protection to activate in Cooper Notification SP40S?
    • T
      Travis WhiteAug 27, 2025
      If the Audio Over current Protection is active in your Cooper Notification Conference System, check the TB4, Audio Out terminals, and speaker wiring for shorts. Ensure the speakers are tapped correctly. You can also try resetting the SP40S by removing AC and Battery power, waiting 30 seconds, and then reapplying power (AC first, then batteries). If the issue persists, consider replacing the motherboard.
  • A
    Anthony TaylorAug 27, 2025
    How to fix missing or low AC input voltage in Cooper Notification SP40S Conference System?
    • B
      baldwintracyAug 27, 2025
      If the AC input voltage is missing or low in your Cooper Notification Conference System, check fuse F2 on the motherboard and replace it if necessary (250V, 10A). Check for AC voltage at TB9. If voltage is not present, check the wiring and circuit breaker. If voltage is present and fuse F2 is not open, consider replacing the motherboard.
  • M
    Mary BarberAug 25, 2025
    What to do if the battery voltage is low or missing in my Cooper Notification Conference System?
    • D
      Deborah RiosAug 26, 2025
      If the battery voltage is below 20.4 VDC or the battery is missing in your Cooper Notification Conference System, first check the battery compartment for the presence of batteries and install them if they are missing. Ensure the batteries are properly wired. Check for 24VDC at the (+, -) BAT connection at TB10 on the motherboard. If the voltage is below 18.5VDC, the battery charging section of the motherboard may be inoperable, consider replacing the motherboard. If all steps are satisfied, replace the batteries.
  • R
    Rhonda GreenAug 23, 2025
    How to troubleshoot missing AC and battery power in Cooper Notification Conference System?
    • D
      davidfriedmanAug 23, 2025
      If AC and battery power are missing in your Cooper Notification Conference System, check for AC voltage at TB9 on the motherboard. If voltage isn't present, inspect the AC input wiring. If AC voltage is present, check if fuse F2 is blown and replace the fuse (250V, 10A) if needed.

Summary

2. Safety Precautions

2.3 Compliance with Codes and Standards

Emphasizes compliance with NFPA, UL, NEC, OSHA, and local codes.

2.2 Operational Safety

Warnings about improper installation/testing and static electricity hazards.

3. Overview

3.5 User Interface

Describes the unit's status display and user controls.

3.5.1 Basic Operation of User Interface

Explains how message buttons activate messages and LEDs.

3.5.2.1 Operation of Digital Voice Messages with SP40 S Firmware

Explains DV message activation with timers and priority for SP40S-D.

3.6 Additional Drawings (Terminal Blocks)

Shows terminal block layout and connections.

4. Installation

4.6.2 Checkout Procedure (Power and LEDs)

Step-by-step checkout process including power connections and LED checks.

4.6.2 Checkout Procedure (Message Tests)

Tests microphone, auxiliary, and digital voice messages.

4.6 Performing System Checkout

Guidelines for system testing based on NFPA 72.

4.6.1 System Control Settings

Basic panel setup procedure including controls and terminal blocks.

5. Operation

6. Operating Procedures

7. Periodic Testing and Maintenance

7.2 Periodic Testing

Frequency and equipment to be tested.

7.3 Faulty Equipment

Steps for dealing with malfunctioning modules or equipment.

7.4 Qualified Personnel

Defines "qualified personnel" for testing and maintenance.

8. Troubleshooting

8.2.1 Procedure A (Power Loss)

Troubleshooting power loss conditions.

8.2.4 Procedure D (AC Trouble)

Troubleshooting AC input missing or low conditions.

8.2.6 Procedure F (MIC Issues)

Troubleshooting MIC related issues (missing, plugged in, defective).

8.2.9 Procedure I (STB Open)

Troubleshooting open condition on STB OUT NAC circuit.

8.2.12 Procedure L (AUDIO Open)

Troubleshooting open condition on AUDIO OUT circuit.

8.2.15 Procedure O (SPB SUP Trouble)

Troubleshooting SPB SUP terminals open conditions.

8.2.18 Procedure R (Battery Charger)

Troubleshooting battery charger trouble.

8.2.2 Procedure B (Strobe Over Current)

Troubleshooting over-current states for strobe circuits.

8.2.5 Procedure E (DV Messages)

Troubleshooting missing DV messages or low output voltage.

8.2.7 Procedure G (Amplifier Trouble)

Troubleshooting amplifier issues (short, overload, protection).

8.2.10 Procedure J (AUX IN Trouble)

Troubleshooting AUX IN CC/NAC input circuit open conditions.

8.2.13 Procedure M (Ground Fault)

Troubleshooting ground fault conditions.

8.2.16 Procedure P (Auxiliary Preamp)

Troubleshooting auxiliary preamp trouble.

8.2.19 Procedure S (DV Wiring Trouble)

Troubleshooting DV Contact Closure Wiring issues.

8.2.3 Procedure C (Battery Voltage)

Troubleshooting battery voltage issues.

8.2.8 Procedure H (STB Short)

Troubleshooting short condition on STB OUT NAC circuit.

8.2.11 Procedure K (AUDIO Short)

Troubleshooting short condition on AUDIO OUT circuit.

8.2.14 Procedure N (Interface Trouble)

Troubleshooting interface connection issues.

8.2.17 Procedure Q (Mic Preamp)

Troubleshooting mic preamp trouble.

8.2.20 Procedure T (Noise;Grounding)

Troubleshooting excessive noise from speakers due to grounding.

11. Battery Backup Calculation Worksheet

Cooper Notification SP40S Series Specifications

General IconGeneral
BrandCooper Notification
ModelSP40S Series
CategoryConference System
LanguageEnglish