User Manual
SMP Gateway

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Cooper SMP 16/CP and is the answer not in the manual?

Cooper SMP 16/CP Specifications

General IconGeneral
BrandCooper
ModelSMP 16/CP
CategoryGateway
LanguageEnglish

Summary

Principles of Operation

Configuring the SMP Gateway

Process for establishing relationships between internal components and setting specific configurations.

SMP Tools Overview

SMP Config

Configures SMP Gateway by specifying devices, protocols, links, and data points.

SMP Manager

Configuring the SMP Gateway

Creating Master Protocol Instances

Adding master protocol instances for each device to access via the SMP Gateway.

Configuring the Data Points

Process of defining physical and logical data points for devices connected to the gateway.

Configuring the Communications Links

Setting up serial and TCP/IP communication links for connecting devices and control centers.

Testing the Configuration

Steps for validating, saving, and sending the SMP Gateway configuration.

Connecting the SMP Gateway to a Control Center

Creating Slave Protocol Instances

Steps to create a slave protocol instance for communication with a control center.

Configuring Slave Protocol Instances

Setting protocol parameters and specifying data points for slave instances.

Subscribing to the Master Data Points

Selecting data points from master protocol components for slave instances to subscribe to.

Using the Web Server’s Commissioning Tool

Configuring an SMP Gateway for Commissioning

Enabling the commissioning tool feature on the SMP Gateway using SMP Config.

Activating the Commissioning Feature

Process for activating the commissioning feature via the SMP Gateway's website.

Opening a Commissioning Session

Steps to open a commissioning session after the feature has been activated.

Interconnecting SMP Gateways

Configuring the Slave SMP Gateway

Setting up an Interconnections slave instance on the slave SMP Gateway.

Configuring the Master SMP Gateway

Configuring the Interconnections master instance and importing data points from the slave.

Security

Meeting NERC CIP Requirements

How SMP Gateway meets NERC CIP standards with features like authentication and firewall.

Substation Network Security Considerations

Guidelines for setting up a secure substation LAN and using firewalls.

Managing the Security Database

Steps for customizing security settings, defining users, groups, and policies.

Using Passthrough Connections

Retrieving Event Files From Devices

Using the Annunciator Interface

Setting Up the Annunciator

Configuration steps for the Annunciator, including alarm inputs and display pages.

The SMP Gateway’s Automation Functions

Using Syslog with an SMP Gateway

Redundancy

Redundant Group Operation

Overview of redundant group operation with active and standby SMP Gateways.

Grouping 2 SMP Gateways for Redundancy

Steps to create a redundancy group using SMP Manager and configure group properties.

Time Adjustment

Automatic Clock Adjustment

Ways to automatically adjust the internal clock using GPS, IRIG-B, SNTP, or SCADA protocols.

SMP Tools Remote Access to the SMP Gateway

Using a Dial-Up Connection for DNP3 or IEC 60870-5-101

Updating SMP Gateway’s Software and Tools

Updating the SMP Gateway Software

Steps for updating SMP Gateway firmware, application, and configuration files.

Activating a New License

Troubleshooting

Startup Problems

Troubleshooting common startup issues like missing configuration files or failed protocols.

Communications Problems

Diagnosing communication issues by examining physical, link, and protocol layers.