2KZ/2K0-7
1-3-4
Developer U135 Checking toner motor operation
-
U136 Setting toner near end detection
0/0
U139 Displaying the temperature and humidity outside the
machine
-
U140 Setting developer bias
450/480/480/450/
50/50/50/50/
350/380/380/350
150/180/180/150/
150/150/150/150/
150/180/180/150
36/36/36/36/
36/36/36/36/
36/36/36/36
27/27/27/27/
27/27/27/27/
27/27/27/27
1400/1400/1400/1400/
1000/1000/1000/1000/
1200/1200/1200/1200
0/0/0/0
0/0/0/0
U147 Setting for toner applying operation
0/60
U150 Checking sensors for toner
-
U157 Checking the developing drive time
0/0/0/0
Fuser U161 Setting the fuser control temperature
210/240/
190/110/95/
120/145/
150/150/
125/145/
240/85/45/
200/90
210/240/
190/110/
100/125/
150/155/
155/130/
150/240/90/
50/200/95
U167 Displaying fuser heater temperature
0
U168 Confirmation/setting the fuser drive time
0/0
U169 Confirmation/setting the fuser drive time
-
U199 Displaying fuser heater temperature
-
Operation
panel and
support
equipment
U201 Initializing the touch panel
-
U203 Checking DP operation
-
U207 Checking the operation panel keys
-
U222 Setting the IC card type
Other
U243 Checking the operation of the DP motors
-
U244 Checking the DP switches
-
Section
Item
No.
Content of maintenance item
Initial setting
20ppm 25ppm