values.
1. Press the start key.
2. Select the item to be set.
3. Change the setting value using the cursor left/right keys.
4. Press the start key. The value is set.
Item No. Description
Display Description
Setting
range
Initial setting
20
ppm
25
ppm
Copy Curb(Edge) Prevention temperature of over-
temperature rise under copy
100 to 250 210 210
Curb(Edge) Prevention temperature of over-
temperature rise
100 to 250 240 240
Return(Edge) Return temperature of overtem-
perature rise
100 to 250 190 190
Ready(Edge) Ready display temperature 0 to 200 110 110
Pressure(Press) Pressurizing beginning tempera-
ture
0 to 200 95 100
High speed(Center) Full speed shift temperature 0 to 200 120 125
Ready(Center) Ready display temperature 100 to 200 145 150
Drive(Center) The second stability temperature 100 to 200 150 155
Full speed(Center) Print control temperature 100 to 200 150 155
Wait(Center) Control temperature when being
standing by
100 to 200 125 130
WarmUp Curb(Cen-
ter)
Electric power control temperature
at start-up
0 to 200 145 150
Curb(Center) Prevention temperature of over-
temperature rise
170 to 250 240 240
Low power(Center) Low electric power control
temperature
0 to 200 85 90
Ready(Press) Ready display temperature 0 to 200 45 50
Curb(Press) Prevention temperature of over-
temperature rise
170 to 250 200 200
Wait Offset(Press) Correction temperature when
being standing by