Linus
17
large quantities collect in enclosed spaces. Remember that parts of the device are at operating pressure. Do not
loosen or dismantle any components at operating pressure. An operating instruction is necessary when
changing the gas tank.
3. Intended use
The Linus cooler is designed for cooling beer. Food suitable CO
2
is used for propellant. The cooling of other
drinks or liquids is forbidden.
The inlet temperature of the liquids must not exceed 32°C otherwise the pressure in the refrigeration cycle will
rise above specification.
The energy exchange from the cooling coil to the drink takes place in a liquid bath with water.
No other liquids are endorsed for use in the liquid bath other than water.
4. Installation Requirements
4.1 Installation Sites
Comply with the valid national regulations for installation sites and electrical connections. Ventilation of the
installation sites must be appropriate for device output. Inadequate ventilation of the device will result in its
overheating and being destroyed. Always make certain that no intake or discharge vents are covered.
MiniLinus Linus 40 Linus 60 Linus 80 Linus 120
Heat output in watt 481 690 1239 1716 1900
Air flow in m
3
/hour (freewheeling) 160 200 400 600 900
4.2 Electrical Connections
A socket outlet with an earthing contact featuring a maximum protection of 16 amperes is required.
The line voltage must always be within following tolerances: 230 VAC +6%/-10% / 50 Hz
MiniLinus Linus 40 Linus 60 Linus 80 Linus 120
Power consumption in watts 190 240 495 610 750
If you are operating the Device with a extension cable please note following:
The length of the cable must not excess 50m and must have a conductor cross-section of 1,5mm².
Not mention that may result insufficient power supply and may cause compressor damage.
5. Installation
The device must be installed by a trained service technician.
5.1. CO
2
-Connection
5.1.1 Unit without Air Compressor
You will require a single-wire pressure regulator 3 bar for beer. Please ensure that the maximun permissible
pressure in the beverage container is not exceeded. Connect the pressure regulator to the tanks, using tubing
with an inner diameter of 4 mm.