Linus
21
9. Problems and Troubleshooting
Before looking for problems with the dispense equipment, first check:
Is the flow of electricity to the device interrupted?
Are the beverage containers empty?
Is the CO
2
-cylinder empty?
Are all valves on the CO
2
-cylinder open?
Type of problem Cause Remedy
Beverage too warm while Temperature set to high Adjust the temperature
while compressor is running Condenser dirty Use brush to clean con-
denser between louvres
Too much beverage Examine / reduce out-put
being removed capacity
Beverage too warm and Compressor not call service technician
compressor not running turned on
Electric control defective call service technician
Beverage foams at a tap Product stored too long Connect container
and enriched with CO
2
with fresh product
CO
2
-pressure too high Set pressure
Beverage to warm Check storage
temperature
CO
2
-volume in the CO
2
-pressure too low Set pressure
beverage is too low
10. Waste disposal and environment protection
For many years the Engineers of IMI Cornelius and its customers are working hand in hand to build devices
which are containing no dangerous Materials and which can be easily recycled to 95%.
All devices of IMI Cornelius conform the EG-Guideline 2002/95EG,2002/96/EG as well as laws for
electronics and electronical devices (germ. ElektroG) from March 2005.
Please do recycle the device at a recycling company nearby.
Attention!
Do not dispose in a public collecting point for private devices.
If required please return the device to your distributor or at any service station of
IMI Cornelius Langenfeld.