4 Installation Requirements
4.1 Installation Sites
Comply with the valid national regulations for installation sites and electrical connections. Ventilation of the
installation sites must be appropriate for unit output. Inadequate ventilation of the unit will result in
overheating and damage. Always make certain that no intake or discharge vents are covered or blocked.
LOOP Style XL
Heat output in watt 945
Air flow in m
3
/hour 400
4.2 Electrical Connections
A socket outlet with an earthed contact featuring a maximum protection of 16 amperes is required.
The line voltage must always be within the following tolerances: 230 VAC +6%/-10% / 50 Hz
LOOP Style XL
Power consumption in watt 790
Should placement of the unit require an extension cable, please note the following points:
Cable length must not exceed 50 meters.
Only use cable with a size of 2.5 mm
2
.
Only one unit is allowed per extension cable.
4.3 Hydraulical connections
The hydraulical connections have to comply to all national mandatory norms, laws and directives. They
must be carried out only by skilled and authorized personnel with appropriate tools.