New 3200-406
Oct., 2009
Cornell Pump Company
5. Install impeller. Apply Loctite 262 to impeller lockscrew threads and shaft threads. Install impeller lockscrew
and impeller washer. Do not lubricate impeller washer and the impeller. Lockscrew should always be new.
See Impeller Lockscrew installation page for torque requirements.
6. Install new gasket. For emergency use, old gaskets should be moist and flat.
7. Install volute sliding it carefully over the register. Bolt volute to backplate.