Checking heater
Where warranted, Homevision® control panel gives a warning in the event of too high humidity,
checks that the heater in the dehumidifier is working as intended.
1. When Homevision® control panel indicates that the dehumidifier is working, place your
hand next to the wet air hose outlet by the foundation wall and verify that the air there is
warm and humid.
2. If the air feels cold, the dehumidifier needs repairing. Contact your retailer.
If in doubt, due to prevailing weather conditions, about whether the air at the outlet is warm or not,
follow the instructions below:
As this inspection must be carried out with the dehumidifier powered, the utmost
caution must be observed. Do not insert your fingers or any tools into the machine!
1. When Homevision® control panel indicates that the dehumidifier is working, remove the
wet air hose from the machine with tools.
2. Place your hand in front of the connector, the pipe on which the hose was installed, and
verify that the air feels warm and humid.
3. Reinstall the wet air hose. If the air feels cold, the dehumidifier needs repairing. Contact
your retailer.
Accessories
The following parts are available as accessories and consumables for CTR 300TT2:
Part number
Designation
20184
Filters