IMPORTANT: SPECIFICALLY, PLEASE NOTE THAT THE GLOBAL LF INVERTER CHARGER SHOULD NOT BE USED IN CONNECTION WITH LIFE SUPPORT SYSTEM OR
OTHER MEDICAL EQUIPMENT OR DEVICES.
BEFORE USING THE INVERTER, YOU NEED READ AND SAVE THE SAFETY INSTRUCTIONS.
Thank you for purchasing a Cosuper product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
Refer to Instruction
Manual
INSTRUCTIONS FOR:
INVERTER CHARGERS PURE SINE WAVE
12V DC INPUT, 2000 & 3000 WATT
MODEL NO’s: CPT2000, CPT3000
1. SAFETY
CPT series Issue: 1 - 14/12/18
DANGER! - Beware, lead-acid batteries generate explosive gases during normal battery operation.
Wash with soap and water immediately if battery acid contacts skin or clothing. If acid enters eye, flush immediately with cool,clean running
water for at least 15 minutes and seek immediate medical attention.
DO NOT smoke or allow a spark or flame in the vicinity of the battery or engine.
If the battery terminals are corroded or dirty, clean them before attaching the leads.
WARNING! To prevent the risk of sparking, short circuit and possible explosion DO NOT drop metal tools in the battery area, or allow them to
touch the battery terminals.
Before attaching to battery, remove personal metallic items such as rings, bracelets, necklaces and watches. A lead acid battery can produce
a short-circuit current which is high enough to weld such items and cause severe burns.
DO NOT expose inverter to rain, snow, spray, bilge or dust. DO NOT cover or obstruct ventilations.
2. INTRODUCTION
This pure sine wave inverter charger is the combination of inverter, battery charger and AC autotranser switch. This complete system with a peak
Power tools- circular saws, drills, grinders, sanders, buffers, weed and hedge trimmers, air compressor and etc.
Office equipment- computers, printers, monitors, facsimile machines, scanners and etc.
Household appliances- vacuum, fans, lights, TV, refrigerator, microwave, coffee machine, toaster, blender and etc.
Industrial equipment- metal halide lamp, high pressure sodium lamp and etc.
NOTE, The inverter working time with full loads cannot over 60 minutes.
conversion efficiency of 88%.
CPT is a inverter charger with backup UPS function. When utility AC pow
er cuts off, the transfer relay is de-enegizered and the load is transferred
to inverter ouput. Once the qualified AC utility power is restored, the relay will be energized and the load is automatically reconnected to AC utility.
This inverter charger unit is easily customized to battery priority via a DIP switch which helps extract maximum power from battery in renewable
energy systems. Therefore this inverter charger is suitable for renewable
energy system, RV, marnine and emergency appliances.
3. SPECIFICATION
>>Battery
>>General Information
>>Applications
>>Model Information
>>Inverter/Charger
MAKE SURE at least 10CM of clearance on DC terminal side and rear heat dissipation side, and 3CM of clearance on body side for air flow.
MAKE SURE existing wiring is in good electrical condition. DO NOT operate inverter charger with damaged or substandard wiring.
DO NOT install in compartments containing batteries or flammable materials or in locations which require ignition protected equipment.
DO NOT disassemble this inverter charger. Internal capacitors remain charged after all power is disconnected. Attempting to service this
inverter charger by yourself may cause electrical shock or fire.
WARNING! Disconnect both AC and DC power from the inverter charger before any maintenance. Turning off controls will not reduce risk.
DANGER! The output side of inverter’s AC wiring at no time be no connected to public power or a generator. Beware the wiring connection.
Typical part number ►
COSUPER inverter charger
Power range
2000=2000W
3000=3000W
Rated AC input& Output voltage
1=120VAC
DC range
12=12V

Other manuals for Cosuper CPT Series

Questions and Answers

  • K
    Kenneth AcostaJul 30, 2025
    What to do if Cosuper Battery Charger is inoperative and won't accept AC?
    • J
      John McculloughJul 30, 2025
      If your Cosuper Battery Charger is inoperative and not accepting AC, it might be due to the AC voltage dropping out of the inverter charger's AC input range. Check the AC voltage to ensure it's within the proper voltage and frequency.
  • L
    laura80Aug 3, 2025
    Why Cosuper Battery Charger supplies a lower charge rate?
    • S
      ssmithAug 4, 2025
      If your Cosuper Battery Charger is supplying a lower charge rate, it could be due to several reasons: * Improperly set charger controls. In this case you should refer to section on adjusting the 'charge rate'. * Low AC input voltage. You should source qualified AC power. * Loose battery or AC input connection. You should check all DC/AC connections.
  • A
    Anthony RiceAug 8, 2025
    What to do if Cosuper CPT turns OFF while charging from a generator?
    • R
      Ronald HoffmanAug 8, 2025
      If your Cosuper Battery Charger turns off while charging from a generator, it's likely due to high AC input voltage from the generator. Try loading the generator down with a heavy load or turning down the generator's output voltage.
  • J
    Julie FosterAug 12, 2025
    How to fix low AC output voltage on Cosuper Battery Charger?
    • D
      Deborah WilliamsAug 12, 2025
      If the AC output voltage of your Cosuper Battery Charger is low and the inverter turns loads off quickly, it's likely due to low battery voltage and capacity. Check the battery condition and recharge it if possible.
  • D
    Derrick WilliamsAug 16, 2025
    What to do if Cosuper CPT won't turn on?
    • P
      pwoodsAug 16, 2025
      If your Cosuper Battery Charger won't turn on during initial power up, it could be due to the following reasons: * Batteries are not connected. * Loose battery-side connections. * Low battery voltage. Check the batteries and cable connections, inspect the DC fuse and breaker, and charge the battery.
  • D
    David NortonAug 21, 2025
    Why is there no AC output voltage on my Cosuper CPT Battery Charger?
    • V
      Vincent McgeeAug 21, 2025
      If there is no AC output voltage and no indicator lights are on, it means that your Cosuper Battery Charger has been manually transitioned to OFF mode. To fix this, press the switch to the ON position.
  • R
    Reginald RichmondAug 26, 2025
    Why is there noise from transformer/case of Cosuper Battery Charger?
    • F
      Frank OnealAug 26, 2025
      The noise from the transformer or case of your Cosuper Battery Charger is caused by applying specific loads such as an electrical heater. Remove the loads to eliminate the noise.

Summary

1. SAFETY

Battery Safety Precautions

Safety precautions for handling lead-acid batteries, including gas generation and acid contact.

Inverter;Charger Safety

Safety precautions for the inverter/charger unit, including environmental exposure, ventilation, and internal components.

Electrical Performance

Automatic Transfer and UPS Function

DIP Switch Configuration

LED Indicators

Audible Alarms

3. INSTALLATION

Battery Explosion Hazard

Mounting Instructions

Connecting the Inverter

Operation Sequence

4. INDICATE & ALARM

Frequently Asked Questions (FAQ)

Troubleshooting Common Issues

Addresses inverter shutdown, appliance operation, and reverse polarity damage.

6. SPECIFICATION

Power Input;Output and AC Charger Specs

Lists power, output, AC charger voltage, charge current, and transfer time details.

Cosuper CPT Series Specifications

General IconGeneral
DC Output Voltage12V / 24V
Output Current10A/20A
ProtectionReverse Polarity Protection, Short Circuit Protection, Over Voltage Protection
CoolingFan
Operating Temperature-20°C to +50°C
Charging PortsSingle
Charging Power120W/240W