COVAL • 26120 Montélier • France • Tél : 00 33 (0)4 75 59 91 91 • E-Mail : coval@coval.com
1
v 03
Dimensions and characteristics may be modified without notice.
®
Electronic vacuum switch PSA100C
1 Display
Mode To select the different modes
+/- To change settings
LED output 1 & 2 Switching indicators
2 Switch output 1 adjustment
To adjust switch output 1 threshold, push the “mode” key
1 time.
The display is alternating between “H1” and the adjusted
value.
To change this adjustment, push “+/-” keys until the
requested value is displayed.
After 5 seconds, the
chosen value registers
automatically and the
screen returns to the
vacuum display.
To change this adjustment, push “+/-” keys to display the
requested value.
After 5 seconds, the chosen value registers
automatically and the screen returns to the vacuum
display.
3 Switch output 2 adjustment
To adjust the switch output 2 threshold, push the “mode”
key 2 times quickly.
The display is alternating between “H2” and the adjusted
value.
To change this adjustment, push “+/-” keys to display the
requested value.
After 5 seconds, the
chosen value registers
automatically and the
screen returns to the
vacuum display.
Mode
+
-
To adjust the hysteresis
h1, push the mode key.
The display is alterna-
ting between “h1” and
the adjusted value.
or
To adjust the hysteresis
h2, push the mode key.
The display is alterna-
ting between “h2” and
the adjusted value.
or
Attendre
5 sec.
- 1
46H1
+
75H1
75
1xM
-
Attendre
5 sec.
- 2
46H2
+
65H2
75
2xM
-
+
-
07h1
75
Attendre
5 sec.
10h1
nc
no
+
-
07h2
10
Attendre
5 sec.
After 5 seconds, the
chosen value registers
automatically and the
screen returns to the
vacuum display.
To adjust output 1
configuration, push
the “mode” key.
To change this adjust-
ment, push “+/-” keys.
NO or NC are
displayed.
or
Question and Answer IconNeed help?

Do you have a question about the coval PSA100C and is the answer not in the manual?

coval PSA100C Specifications

General IconGeneral
Brandcoval
ModelPSA100C
CategorySwitch
LanguageEnglish

Summary

Display

Mode Selection

Select different operating modes for the vacuum switch.

Settings Adjustment

Adjust device settings using the +/- keys.

LED Indicators

Information on LED output indicators for switching status.

Switch Output 1 Adjustment

Adjust Threshold

Adjust the switch output 1 threshold using mode and +/- keys.

Adjust Hysteresis

Adjust the hysteresis for switch output 1 using mode and +/- keys.

Adjust Configuration

Configure switch output 1 (NO/NC) using mode and +/- keys.

Switch Output 2 Adjustment

Adjust Threshold

Adjust the switch output 2 threshold using mode and +/- keys.

Adjust Hysteresis

Adjust the hysteresis for switch output 2 using mode and +/- keys.

Adjust Configuration

Configure switch output 2 (NO/NC) using mode and +/- keys.

Locking and Unlocking Settings

Activate Locking

Activate settings lock (LC) by pressing mode and '-' keys.

Deactivate Locking

Deactivate settings lock (UC) by pressing mode and '-' keys.

Display Rotation

Factory Settings

Preset Values

Preset Values Output 1

Displays preset values H1 and h1 for output 1.

Preset Values Output 2

Displays preset values H2 and h2 for output 2.

Tightening Couple