26
25
Maintenance
FILTER REPLACEMENT METHOD
FILTER REPLACEMENT / FILTER REPLACEMENT METHOD
1. Close the water supply valve and completely drain all water from inside the product, and
then pull out the power plug.
2. Remove ttings connecting the lter you wish to exchange, and then exchange the lter
(use the correct tool to remove the ttings).
3. Insert the lower part of the side cover precisely in its place.
Exchange the lter
After exchanging the lter, connect ttings and hoses precisely and
check that there are no leaks. Be sure to rst drain puried water.
Tips
Use new lters only after washing.
- Neo-Sense lter: Install after washing with source water for about 1 minute.
- Membrane (RO) lter: Install the ltered water valve after washing with
source water for about 5 minutes.
- Nanotrap lter: Flush with feed water for 3 minutes. Then install the lter.
- Plus Inno-Sense Filter: Install with no separate ushing.
Tips