Water Filtration System Performance Data Sheet
Model: CHP-590L
This system has been tested and certied by the Water Quality Association according to NSF/ANSI 42, 53 and 58 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specied in NSF/ANSI 42,53,58 and 372.
Substance
Inuent Challenge Concentration
(mg/L unless specied)
Maximum Allowable Product Water
Concentration
(mg/L unless specied)
Percent Reduction
(%)
Arsenic (Pentavalent) 0.050 ± 10% 0.010 97.8
Barium 10.0 ± 10% 2.0 97.3
Radium 226/228 25 pCi/L 5 pCi/L 80
Cadmium 0.03 ± 10% 0.005 98.4
Chromium (Hexavalent) 0.3 ± 10% 0.1 98.6
Chromium (Trivalent) 0.3 ± 10% 0.1 99.4
Lead 0.15 ± 10% 0.010 99.3
Copper 3.0 ± 10% 1.3 98
Selenium 0.10 ± 10% 0.05 98.4
TDS 750 ± 40 187 92.4
Aesthetic Chlorine 2.0 ± 10% ≥ 50% reduction 72.8
VOC* 0.300 ± 10% ≥ 95% reduction 99.8
While testing was performed under laboratory conditions, actual performance may vary.
General Operating Information:
Rated Capacity
290 gallons (for VOC)
5 000 gallons (for Aesthetic Chlorine)
Min-Max operating pressure: 20 ~ 120 psi (1.4 ~ 8.4 kgf/cm
2
)
Min-Max feed water temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
Rated Service Flow 0.07 GPM
Daily Water Production Rate 67.6 GPD
Product Eciency Rating 31.8 %
Electrical Requirements:
Refer to the rating plate.
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
• Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
• The inuent water to the system shall include the following characteristics:
o No organic solvents
o Chlorine: < 2 mg/L
o pH: 7 - 8
o Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
o Iron: < 2 mg/L
o Turbidity: < 1 NTU
o Hardness: < 1 000 mg/L