INSTALLATION, OPERATION, AND
PREVENTATIVE MAINTENANCE
MANUAL
INDOOR SSPA
P/N 01040244R7
For Use With Model Numbers...
Service Center Headquarters and Design Center
West Coast Operations
811 Hansen Way
Palo Alto, CA 94303
Manufacturing
East Coast Operations
45 River Drive
Georgetown, ON
Canada L7G 2J4
S5CI
S4UI
S5XI

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the CPI S5CIA and is the answer not in the manual?

Summary

Chapter 1 Introduction

1.1 Overview

General introduction to the chapter's content and scope.

1.2 General Description

Details the SSPA's construction, components, and basic functionality.

1.3 Standard Features

Lists the built-in capabilities and characteristics of the SSPA.

1.3.1 Compact Rack Height

Highlights the SSPA's space-saving design for rack mounting.

1.3.2 Forward and Reflected RF Power Metering

Describes the capability to measure transmitted and reflected RF power.

1.3.3 Real Time Clock

Mentions the internal clock for timestamping events and logs.

1.3.4 Local or Remote M&C

Explains the options for controlling and monitoring the SSPA.

1.3.5 Graphical Display

Details the front panel display for status and metering information.

1.4 Options

Introduces available optional equipment and configurations.

1.4.1 Remote Control Panel (1 RU)

Describes an optional rack-mountable panel for remote operation.

1.4.2 Block-Up Converter (BUC)

Explains the option to integrate a BUC for L-band to microwave conversion.

1.4.3 BUC Bypass

Details the functionality to bypass the BUC for direct signal input.

1.4.4 Redundant Power Supplies

Describes the option for increased reliability with multiple power modules.

1.4.5 Transient Surge Suppression

Explains the protection module against voltage surges.

1.4.6 Ethernet LAN Interface

Describes the connectivity option for network monitoring and control.

1.4.7 Redundant;Phase Combined Switch System

Details options for system redundancy and phase combining.

1.4.8 Input and Output Power Sampling Ports

Explains ports for monitoring input/output signal levels.

1.4.9 Exhaust Duct

Describes the accessory for directing hot air away from the unit.

1.5 About This Manual

Provides general information regarding the manual's structure and purpose.

1.6 Conventions

Explains symbols, warnings, and text formatting used in the manual.

1.6.1 Notes and Cautions

Details general guidance, warnings, and potential hazards.

1.6.2 Electrical or RF Warnings

Highlights safety warnings related to electrical and RF hazards.

1.6.3 Text Conventions

Explains specific formatting used for text, such as capitalization and italics.

Chapter 2 Unpacking & Installation

2.1 Overview

Provides an overview of the chapter's procedures for site prep, unpacking, and connections.

2.2 Pre-inspection

Instructions for inspecting shipping containers for damage before unpacking.

2.3 Unpacking

Steps for safely removing equipment and accessories from shipping containers.

2.3.1 Equipment and Accessories

Lists items to be unpacked from the shipping container.

2.3.2 Check Packing Slips

Procedure to verify received items against the packing slips.

2.3.3 Post Unpacking Inspection

Guidance for inspecting unpacked equipment for damage.

2.4 Location of Installation

Specifies suitable indoor locations for SSPA installation.

2.5 Preparing For Installation

Outlines essential checks before commencing the installation process.

2.6 Installation

Details the procedures for installing the Indoor SSPA.

2.6.1 Mechanical Installation

Describes how to physically mount the SSPA into a rack.

2.6.2 Grounding

Provides instructions for proper grounding for safety and equipment protection.

2.6.3 Cooling Considerations

Discusses airflow requirements and heat dissipation for optimal performance.

2.6.4 Electrical Power Connections

Details how to connect the SSPA to the primary AC power source.

2.6.4.1 Prime Power

Specific instructions for connecting the main AC power input.

2.6.5 Waveguide Connections

Provides instructions for connecting waveguide flanges for RF signal path.

2.6.6 RF Coaxial Connections

Details the procedures for making RF coaxial cable connections.

2.6.6.1 RF Input (J2)

Specifies the RF input port and connection requirements.

2.6.6.2 RF Output Monitor (J4) (Optional)

Describes the optional port for monitoring RF output signal.

2.6.6.3 RF Input Monitor (J5) (Optional)

Describes the optional port for monitoring RF input signal.

2.6.6.4 BUC Input with BUC Bypass (J16) (Optional)

Specifies the L-Band input port for BUC when bypass is used.

2.6.6.5 BUC Bypass (J17) (Optional)

Details the connection for BUC bypass functionality.

Chapter 3 External Interfaces

3.1 Overview

Introduces the external interfaces available on the SSPA for connectivity.

3.1.1 RS-232 Serial Port

Describes the RS-232 serial port for computer communication.

3.1.2 RS-422;485 Serial Port

Details the RS-422/485 serial port for remote monitoring and control.

3.1.3 Diagnostic Interface

Explains the interface used solely for CPI diagnostic purposes.

3.1.4 Discrete Interface

Describes the interface for monitoring critical parameters via dry contacts.

3.1.5 Ethernet Interface Connector (J14) (Optional)

Details the Ethernet port for network-based control and monitoring.

Chapter 4 Initial Power On & Checkout

4.1 Overview

Introduces procedures for initial power-on and functional checkout.

4.2 Pre-Power on Procedure

Lists essential checks and conditions before applying power.

4.3 Using the Control Panel

Explains how to navigate and operate the SSPA using the front panel.

4.3.1 Data Organization

Describes how information is structured on the SSPA's display screens.

4.3.2 Navigation

Explains how to use the control panel keys to navigate menus and fields.

4.3.2.1 Menu Key

Details the function of the MENU key for accessing system menus.

4.3.2.2 Set Pwr Key

Describes the SET PWR key for adjusting output power and attenuation.

4.3.2.3 Arrow Keys

Explains the use of arrow keys for menu navigation and data adjustment.

4.3.2.4 Enter Key

Details the function of the ENTER key for menu selection and saving data.

4.4 Power-On and Checkout

Step-by-step guide for powering on and verifying SSPA operation.

4.4.1 Initial Check

Describes the initial power-on self-test and verification sequence.

4.4.2 User Preference Settings

Instructions for configuring user-specific settings and preferences.

4.4.3 Setting Trip Limits

Explains how to set alarm and fault trip points for the SSPA.

4.4.4 Verifying Meter Readings

Procedures to verify meter readings and SSPA functionality.

4.4.5 IP and CIF Setup

Guides on configuring IP and CIF settings for remote communication.

4.4.5.1 IP Setup

Details on setting the IP address, mask, and gateway for network connectivity.

4.4.5.2 CIF Setup

Instructions for configuring CIF serial settings for communication.

4.4.6 Activating Computer Control

Explains how to enable and configure computer control of the SSPA.

Chapter 5 Operation

5.1 Overview

Provides an overview of SSPA operation and control panel usage.

5.2 Operational Overview

Describes basic operation using control keys, display, and self-test.

5.3 Control Panel

Details the functions and elements of the SSPA's front panel interface.

5.3.1 The On;Off Push Button

Explains the operation of the power button and its indicator status.

5.3.2 LED Indicators

Describes the meaning of the front panel LED status indicators.

5.3.3 Main Menu Display Screens

Overview of the main screen, RF metering, PSU, and fan speed displays.

5.3.4 Main Control Keys

Defines the functions of the primary control keys (TRANSMIT, STANDBY, RESET).

5.3.5 Menu Key

Explains how to navigate the menu system using the MENU key.

5.3.5.1 Event Log

Describes how to access and view the SSPA's event log entries.

5.3.5.2 Setup

Instructions for accessing and modifying various system setup parameters.

5.3.5.3 Calibration

Details procedures for calibrating RF output, input, and blanking settings.

5.3.5.4 Trip Points

Explains how to view and set alarm and fault trip points.

5.3.5.5 Screen Configuration

Instructions for customizing the data displayed on the main screen.

5.3.5.6 Version

Information on viewing SSPA hardware and software version details.

5.3.5.7 Switch System

Details on controlling the optional switch system via the menu.

5.3.6 Set Power

Explains how to adjust RF output power, attenuation, and power modes.

5.3.6.1 Changing Attenuation

Procedure for adjusting the SSPA's RF attenuation level.

5.3.6.2 RF Set Points

How to set RF output setpoints for automatic or manual power control.

5.3.6.3 Changing Power Modes

Instructions on switching between manual and ALC power modes.

5.4 Remote Operation via Web Interface

Guides for operating the SSPA remotely using a web browser.

5.4.1 PC Setup

Steps for configuring a PC to connect to the SSPA via Ethernet.

5.4.2 Connecting to the Amplifier

Procedure to establish communication between the PC and the SSPA.

5.4.3 Navigation

Explains how to navigate through the SSPA's web interface screens.

5.4.4 Amp Status Screen

Details the Amp Status screen displaying monitored parameters and states.

5.4.5 Amp Info Screen

Describes the Amp Info screen for viewing serial number and firmware versions.

5.4.6 Event Log Screen

Explains how to view the event log data through the web interface.

5.4.7 Setpoints Screen

Details how to view and adjust setpoints via the web interface.

5.4.8 Config Screen

Instructions for configuring relays, BUC type, and fan optimization.

5.4.9 IP Settings Screen

Explains how to set the SSPA's IP address and network configuration.

5.4.10 Email Screen

Details how to configure email notifications for alarms and logs.

5.4.11 Set Login Screen

Instructions for changing user login name and password.

5.4.12 Time Screen

Explains how to set the SSPA's internal time and date.

5.4.13 Options Screen

Details how to configure prompt settings for state changes.

5.4.14 Switch Ctrl Screen

Describes control of the optional switch system via the web interface.

5.5 Shutdown and Recovery

Procedures for safely shutting down and recovering the SSPA.

5.5.1 AC Power Interruption

Explains SSPA behavior during and after AC power interruptions.

5.5.2 Emergency Shutdown

Provides instructions for performing an emergency shutdown.

Chapter 6 Maintenance

6.1 Overview

Introduces maintenance procedures, test equipment, and ESD guidelines.

6.2 Scheduled Preventive Maintenance

Outlines routine maintenance tasks required for safe and effective operation.

6.3 Operators Preventative Maintenance

Lists maintenance tasks that can be performed by the operator.

6.3.1 Visual Inspection

Details the steps for visually inspecting the SSPA for defects.

6.3.2 Unit Cleaning

Provides guidance on cleaning the SSPA chassis and connections.

6.3.3 Air Filter Cleaning

Instructions for cleaning the removable air intake filter.

6.3.4 Fan Inspection

Guidance on inspecting fans for abnormal vibration or sound.

6.4 Technicians Preventative Maintenance

Lists advanced maintenance tasks requiring trained service personnel.

6.4.1 Initial Power-On Check

Describes performing the initial power-on check periodically.

6.4.2 Air System Maintenance

Details checks for airflow and contamination to ensure proper cooling.

6.4.3 Run Performance Tests

Instructions for running performance tests annually.

6.4.4 Fan Replacement

Procedures for replacing SSPA fans after specified operating hours.

6.5 Performance Testing

Provides procedures for testing power, gain, and radiation levels.

6.5.1 Power and Gain Performance Test

Details the steps to test the SSPA's power and gain characteristics.

6.5.2 RF Radiation Measurement

Instructions for measuring RF leakage levels around the SSPA.

6.6 Protecting Parts from Electrostatic Discharge

Guidelines and precautions for preventing ESD damage to components.

6.6.1 Precautions

Lists essential precautions for handling static-sensitive electronic parts.

6.6.2 Workstation Practices

Describes requirements for setting up and maintaining static-safe workstations.

6.6.3 Workstation Upkeep

Details weekly checks and cleaning procedures for static-safe workstations.

6.6.4 Packaging

Provides guidelines for properly packaging parts for storage or transport.

6.7 Customer Service

Information on contacting CPI for service and support.

Chapter 7 SSPA Functional Tree

7.1 Functional Trees

Describes the roadmap for navigating SSPA functions via the front panel.

Chapter 8 Redundant Switch Option

8.1 Overview

Introduction to the optional 1:1 and 1:2 redundant switch assemblies.

8.2 Equipment Description

Details the components of the 1:1 switch assembly and SIM controller.

8.3 Equipment Set Up

Provides procedures for setting up the SIM controller and amplifiers.

8.3.1 SIM Controller Setup

Instructions for configuring the SIM controller's dipswitch settings.

8.3.2 Amplifier Setup

Steps for setting up the amplifier parameters for switch system operation.

8.4 Installation

Describes the installation process for switch systems with/without optional cabinets.

8.4.1 Switch System with an Optional Cabinet

Installation guide for the switch system housed in an optional cabinet.

8.4.2 Switch System Without an Optional Cabinet

Installation guide for the switch system mounted in a user's cabinet.

8.5 Operation

Explains how to operate the switch assembly in manual and auto modes.

8.6 Drawing List

Lists the available drawings related to the switch system.

Chapter 9 Drawings

Table 9-1. Indoor SSPA Drawings

Lists the drawing numbers and titles for the Indoor SSPA.

Table 9-1. Indoor SSPA Drawings (continued)

Continues the list of drawing numbers and titles for the Indoor SSPA.

Appendix B L-Band BUC Option

Table B-1. Example of L-Band To Ku-Band Conversion

Provides example frequency conversions for L-Band BUCs.

BUC alarm signal description

Describes the BUC alarm signal and its reporting mechanism.

BUC alarm setting

Explains how the BUC alarm can be configured as a fault.

CPI S5CIA Specifications

General IconGeneral
BrandCPI
ModelS5CIA
CategoryAmplifier
LanguageEnglish