CS90
Continuous Siphon Overflow
CPR’s Continuous Siphon Overflows provide the most efficient means of getting water to an external
filter without expensive modifications to the tank. These precision-engineered overflows skim water from
the surface of your aquarium at flow rates up to six times greater than units with tubes. Advantages
such as water level adjustment, quiet operation, grated overflow, and a black top to reduce algae growth
all make the CPR Continuous Siphon Overflow the best on the market. Please read through the set up
directions before and during the actual set up to ensure it is done correctly.
To place your overflow into operation:
1. Open the packaging carefully and inspect the unit for damaged or missing parts. You should have:
(1) Overflow body
(1) Screen and sponge
(1) Vent tube with small “O” ring
(1) Bulkhead assembly
(3) Adjustment screws
(1) Air line
(1) Aqua Lifter pump and Acrylic Lid (included in Deluxe models)
If any items are damaged or missing, please contact your dealer immediately.
2. Before using the overflow for the first time it is important to decide where to position the unit. It is
best to have the overflow as far away from the inflow as possible to reduce turbulence. It is also
important to check the capacity of your sump as well as the flow rate of your return pump on your
filtration system to prevent possible overflow. It will be necessary to add water to the system after
it begins running. The amount of water that you will need to add will depend on the sump size and
design.
3. Assemble the bulkhead fitting as shown in diagram A. Insert the pre-filter screen into the bulkhead
and place the pre-filter sponge over the screen. Insert the vent tube into the hole at the top of the
pre-filter screen. The “O” ring can slide up or down to adjust the height of the vent tube once the
unit is operational.
4. Connect the bulkhead fitting to the hose going into your filtration system. You should use 1”
Schedule 40 PVC inserted into the slip fitting inside the bulkhead. The PVC can be run directly into
the filter or can be attached to 1 1/4” flexible line (using the optional PVC adapter available at Ameka
Aquatics.com). The fewest bends in the line will ensure the quietest operation. To prevent leakage
from where the PVC inserts into the bulkhead, you should use PVC cement to secure it into place. If
using adapters other than PVC, All-Purpose Cement should be used to secure the plumbing in place.
5. Place the unit on the edge of your tank and allow the water to fill the front chamber. Adjust the
lower adjustment screws so that the unit is parallel to the back of the tank.
Question and Answer IconNeed help?

Do you have a question about the CPR CS90 and is the answer not in the manual?

Summary

Continuous Siphon Overflow Setup and Operation

Inspect and Verify Components

Check packaging for damaged or missing parts. List of supplied items for inspection.

Positioning and System Capacity Check

Decide overflow location and verify sump capacity and return pump flow rate.

Bulkhead Assembly Instructions

Assemble bulkhead fitting, insert screen, sponge, and vent tube, adjusting the O-ring.

Plumbing Connections

Connect bulkhead to filtration using PVC, securing with cement to prevent leaks.

Unit Placement and Leveling

Place unit on tank edge, fill front chamber, and adjust screws for leveling.

Adjust Unit Height for Water Level

Fine-tune unit height using top adjustment screws for desired aquarium water level.

Initiate Siphon Operation

Fill overflow and draw out air using methods like Aqua Lifter or Venturi powerhead.

Start Return Pump and Monitor

Plug in return pump, ensure sump submersion, and monitor water levels for consistent operation.

Fine-tune Aquarium Water Level

Adjust aquarium water level using top screws, influencing sump levels and overflow performance.

Reduce Overflow Noise

Minimize flushing noise by adjusting the vent tube position for optimal air escape.

CPR CS90 Specifications

General IconGeneral
BrandCPR
ModelCS90
CategoryWater Pump
LanguageEnglish

Related product manuals