MAINTENANCE AND CARE
PARTS LIST AND WARRANTY
11
Service Mode
This mode should only be entered with direction by technical support or by an authorized service center. This mode enables the testing of each
device controlled by the FX Series’ computer. These devices include the ball valves, vacuum pump, compressor and pressure transducers. This
mode can be located in the “Maintenance Mode”
Field Software Update
Updates to the system software will require use of this mode. Found in the “Maintenance Mode”, an update password and the new software
le installed on a USB drive will be required. Insert the USB stick with the new software update le into the USB port on the back of the control
panel. Go to the and select Follow the displayed directions. Be sure power remains on during this operation.
Display Calibration
Under certain conditions the touch screen may lose its calibration (i.e., touches on the screen don’t result in the desired result). If pressing
a function on the screen does not actuate the function, or engages an adjacent function, the screen needs to be calibrated. To do so, turn the
machine’s power off. Then while pressing and holding any spot on the touch screen turn the power back on. A screen set up menu will be
displayed. Select screen calibration and follow the on-screen directions.
Common Part List
WARRANTY & REPAIR POLICY
CPS warranties the FX Series Refrigerant Management Centers are free of manufacturing defects. If a component should fail due to manufac-
turing defect during the rst year in service, it will be repaired or replaced (at our option) at no charge. During the second year, parts failures
caused by defect are covered under warranty. CPS will replace any failed part at no charge. Some failed parts must be returned to CPS. Labor
time and mileage are not covered during the second year in service. CPS will cover the compressor for ve full years of service, limited to the
cost of the compressor only. Failed compressors will require return to CPS. CPS may, at its sole discretion, use reconditioned parts for warranty
repairs.
This guarantee does not apply to components that have been altered, misused, or returned solely in need of eld service maintenance. The
repair policy does not include components that are determined to be beyond economical repair. A component or product being presented for
warranty repair must be accompanied by an original bill of sale and customer contact information. CPS is not responsible for lost refrigerant.
Owners should leak test there equipment regularly and store the unit with all valves closed.
Part Number Description
FX3030X1 FX Series Maintenance Kit—Filter, Vacuum Pump oil and Coupler O-rings
Buy locally
Printer Paper—2.25” x 50’ Thermal Sensitive Paper
QCL1234 Low Side 1234yf Coupler
QCH1234 High Side 1234yf Coupler
FA1234X36 Tank Rell Adapter--1/2 Acme LHT X High Side (R1234YF Virgin tanks)
CRX400T 50lb Recovery Tank
481500 Oil Injection Kit
AR27XH115 Heater Blanket
RIXF Refrigerant Identier Filter
LDA1000H Electronic Leak Detector for all Refrigerants

Related product manuals