Questions and Answers

  • K
    Kathy GarciaAug 20, 2025
    Why is my Craftsman 919.165190 Air Compressor not supplying enough air?
    • A
      April TrujilloAug 20, 2025
      If your compressor isn't supplying enough air, it could be due to prolonged excessive use, meaning the compressor isn't large enough for your air demands. Decrease air usage and check the accessory's air requirements; if they exceed what your compressor provides, you'll need a larger one. Inspect the hose for holes and replace if necessary. A restricted check valve could also be the culprit—remove and clean or replace it. Tighten any loose fittings to eliminate air leaks. Lastly, ensure the air intake filter is clean; clean or replace it, but never operate the compressor without the filter. Refer to the "Air Filter" paragraph in the "Maintenance " section.
  • D
    Dustin MillerAug 23, 2025
    How to fix air leaks at Craftsman 919.165190 fittings?
    • B
      Brian RiveraAug 23, 2025
      If you notice air leaks at the fittings, the tube fittings may not be tight enough. Tighten the fittings where you hear air escaping, and use a soapy water solution to check for leaks. Be careful not to overtighten them.
  • J
    James MartinezAug 26, 2025
    What to do if my Craftsman 919.165190 Air Compressor has excessive tank pressure?
    • M
      melaniepopeAug 26, 2025
      If your air compressor has excessive tank pressure and the safety valve pops off, move the On/Auto/Off lever to the "OFF" position. If the unit doesn't shut off, contact a Trained Service Technician. It may be caused by the pressure switch not shutting off the motor when the compressor reaches its cut-out pressure, or the pressure switch cut-out being set too high.
  • N
    Nancy MccartyAug 27, 2025
    What causes air leaks in a Craftsman Air Compressor tank?
    • C
      Christopher VargasAug 28, 2025
      Air leaks in the air tank or at the welds indicate a defective air tank. The air tank must be replaced. Do not attempt to repair the leak, drill into, weld, or modify the air tank, as this will weaken it and could cause it to rupture or explode.
  • D
    Derek SilvaAug 30, 2025
    What causes air leaks at the pressure switch release valve on a Craftsman Air Compressor?
    • S
      Sarah ReedAug 30, 2025
      Air leaks at the pressure switch release valve indicate a defective pressure switch release valve. Contact a Trained Service Technician.
  • T
    Tammy AlvarezSep 1, 2025
    How to resolve air leaks between the head and valve plate on a Craftsman 919.165190?
    • M
      Mary CarterSep 1, 2025
      Air leaks between the head and valve plate are due to a leaking seal. Contact a Trained Service Technician.
  • R
    Ryan StoutSep 4, 2025
    What to do if a Craftsman 919.165190 regulator knob has a continuous air leak?
    • J
      John McneilSep 4, 2025
      A continuous air leak from the regulator knob indicates a damaged regulator. Replace it.
  • C
    Christopher SampsonSep 6, 2025
    What to do if the Craftsman 919.165190 Air Compressor regulator will not shut off air outlet?
    • B
      Barbara MooreSep 7, 2025
      If the regulator won't shut off the air outlet, the regulator is damaged and needs to be replaced.
  • P
    Pamela RussoSep 9, 2025
    What causes air leaks at or inside the check valve of a Craftsman Air Compressor?
    • J
      Joshua BarronSep 9, 2025
      A defective check valve seat can cause air leaks at the pressure release valve when there's pressure in the tank and the compressor is off. Replace the check valve. Refer to the "To Replace or Clean Check Valve" in the "Service and Adjustment" section.
  • M
    Mr. Timothy MartinezSep 12, 2025
    What causes a knocking noise in a Craftsman 919.165190 and how to fix it?
    • J
      Justin SandovalSep 12, 2025
      A knocking noise could indicate a defect in the safety valve or a defective check valve. Try manually operating the safety valve by pulling on its ring; if it continues to leak, replace it. Also, remove and clean the check valve, or replace it if necessary.

Summary

Warranty Information

Safety Guidelines

Important Safety Instructions

Lists critical safety precautions for operating the air compressor.

Key Hazard Warnings

Covers critical risks like explosion, fire, electrical shock, and unsafe operation.

Installation and Setup

Grounding Instructions

Details electrical grounding requirements to prevent shock hazards.

Operation

How to Use Your Unit

Instructions on starting, stopping, and operating the air compressor.

Maintenance

Service and Adjustments

Troubleshooting Guide

Craftsman 919.165190 Specifications

General IconGeneral
Model Number919.165190
TypePortable
Tank Capacity25 Gallons
Max Pressure150 PSI
MotorInduction
Weight110 lbs
Oil-FreeNo
Max PSI150 PSI
Voltage120V
Amperage15 Amps

Related product manuals