Owner’s Manual
AIR COMPRESSOR
4-gallon
¾ HP
Oil-Free, Belt Drive
Universal Motor and Pump
Model No. 921.152150
®
CAUTION:
Before using this product,
read this manual and follow
all its Safety Rules and
Operating Instructions.
Safety Instructions
Installation & Operation
Maintenance & Storage
Troubleshooting Guide
Parts List
Español, p. 10
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com
03/31/2008
Part No. E152150

Questions and Answers

  • C
    Caroline RobertsonAug 14, 2025
    What to do if my Craftsman 921.152150 motor will not start?
    • C
      Courtney CooperAug 14, 2025
      First, ensure the power cord is properly plugged in and the switch is turned on. Check your circuit box for the correct size fuse. If the fuse has tripped, reset it and attempt to restart the unit. If the fuse repeatedly trips, consider replacing the check valve or contacting a service technician.
  • D
    Dr. Amanda PrinceAug 17, 2025
    What to do if my Craftsman 921.152150 Air Compressor has excessive tank pressure?
    • R
      Ryan WilliamsAug 17, 2025
      Move the Auto-On/Off lever to the Off position. If the unit doesn’t shut off, unplug it from the power source and contact a service technician.
  • M
    Mr. Chad ClarkAug 21, 2025
    How to fix air leaks between the head and cylinder of my Craftsman 921.152150 Air Compressor?
    • T
      Teresa WilliamsAug 21, 2025
      Ensure that the head bolts have the proper torque. If the leak persists, it is recommended to contact a service technician.
  • K
    Katie GallegosAug 26, 2025
    What to do if my Craftsman 921.152150 leaks air from the tank body or tank welds?
    • D
      Deanna SmithAug 26, 2025
      Never drill into, weld, or modify the air tank, as this will weaken it and could cause it to rupture or explode. The compressor cannot be repaired, so discontinue using it.
  • V
    Vickie KirkAug 29, 2025
    What to do if there's excessive moisture in the discharge air from my Craftsman 921.152150 Air Compressor?
    • B
      Brooke JonesAug 29, 2025
      If you notice excessive moisture in the discharge air, drain the tank after each use to remove water. Remember that high humidity environments can cause excessive condensation. Consider using water filters on your air line. Also, ensure the compressor’s air output is greater than your tool’s air consumption rate. Note that water condensation is not caused by compressor malfunction.
  • L
    lawrencemitchellSep 1, 2025
    Why is my Craftsman 921.152150 Air Compressor leaking air from the safety valve?
    • J
      Jeffrey JimenezSep 1, 2025
      Try operating the safety valve manually by pulling on the ring. If the valve continues to leak when in the closed position, it should be replaced.
  • B
    Brent HughesSep 5, 2025
    What to do if regulated pressure gauge drops when using an accessory with my Craftsman 921.152150 Air Compressor?
    • H
      howard43Sep 5, 2025
      If there is an excessive pressure drop when using an accessory, replace the regulator. Remember to adjust the regulated pressure under flow conditions (while the accessory is being used). It is normal for the gauge to show minimal pressure loss during initial use of the tool.
  • J
    jay66Sep 9, 2025
    How to resolve air leaks at the check valve of my Craftsman 921.152150 Air Compressor?
    • M
      michellemorganSep 9, 2025
      If you have a defective check valve resulting in a constant air leak at the pressure relief valve when there is pressure in the tank and the compressor is shut off, drain the tank. Then, remove and either clean or replace the check valve.

Summary

Safety Symbols

Important Safety Instructions and Guidelines

Read and understand all safety rules and operating instructions before using this equipment.

Risk of Breathing

Risk of Electrical Shock

Risk of Explosion or Fire

Risk of Bursting

Parts & Features

Installation & Assembly

Grounding Instructions

Essential safety steps to ensure proper grounding and prevent electric shock.

Operating Procedures

Daily Start-Up Procedures

Detailed steps for preparing and starting the compressor for daily operation.

Maintenance

Maintenance Schedule

Schedule for checking safety valve, unit, tank, and power cord before each use or daily.

Troubleshooting Guide

Parts List

Craftsman 921.152150 Specifications

General IconGeneral
Model Number921.152150
Power SourceElectric
Tank Size6 Gallons
Max PSI150 PSI
CFM at 90 PSI2.6 CFM
Voltage120V
Amperage12 Amps
Pump TypeOil-Free
TypePortable
Horsepower1.5 HP