Testing
Procedures:
A.
Locate
the
video
test
equipment,
at
a
point
where
the
video
display
and
character
to
be
tested,
can
be
viewed
simultaneously.
1.
Connect
the
cable
from
the
audio
output
#2,
on
the
Tape
Deck,
to
the
tape
select
box,
(Front
Panel)
input
channel
#3
or
#4.
2.
The
correct
input
channel
is
determined
by
selecting
which
character
is
to
be
stimulated,
channel
#3
is
the
top
drawer
and
channel
#4
is
the
bottom
drawer.
(see
Bit,
Valve
and
Movement
Charts,
Pages
1-011
thru
1-014)
3.
Power
up
the
video
tape
deck.
4.
Load
the
tape
and
rewind
it
completely.
5.
Set
the
unit
counter
to
zero.
B.
Play
the
tape
and
follow
the
adjustment
procedures
described
below.
View
the
tape
long
enough
to
correctly
determine
that
the
movement
is
truly
out
of
adjustment.
(Do
Not
adjust
the
Flow
Control
unless
you
are
sure
the
movement
needs
adjusting)
The
video
display
and
character
must
be
synchronized
exactly.
If
a
movement
is
in
question:
1.
Isolate
the
valve
in
the
valve
bank
that
operates
the
movement
in
question.
(see
"Bit,
Valve
and
Movement
Charts",
Pages
1-011
thru
1-014)
Manually
operate
the
valve,
by
pressing
the
white
manual
override
button
on
the
valve's
solenoid.
2.
Observe
the
movement
by
operating
it
manually.
Look
for
a
smooth
operation
of
the
movement
in
question,
check
for
Cosmetic
parts
that
are
binding,
if
problems
are
present
refer
to
PART
2
Mechanical
Trouble
Shooting.
c.
After
determining
that
the
movement
truly
does
need
adjusting,
turn
the
Flow
Control
Adjustment
screw.
Remember
the
air
coming
out
of
the
cylinder
is
what
you
are
adjusting.
(For
a
explanation
of
the
air
system
see
Pages
3-002
thru
3-030,
The
Air
System.
1-010