LPN000241 REV B
TO INSTALL:
RECESSED HOUSING COMPATIBILITY
Designed to install in standard 6in recessed downlight
housings.
Compatible with most dimmers when used with multiple
fixtures. Consult ww w.creebulb.com/dimmers for a
compatibility chart.
Compatibility of housings may be determined by
measurement of the housing as detailed in the drawing
above (Figure 1).
IMPORTANT SAFEGUARDS
WARNING
circuit breaker before installing or servicing.
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
6. Each lampholder shall be installed only in its intended manner and
orientation.
7. Suitable for Wet Locations.
8. Min. temperature rating of -25°C.
9. Do
10.
11.
SUITABLE FOR INSTALLATION IN A RECESSED CAN WITH
A MAXIMUM OF EIGHT (8) No. 12 AWG THROUGH-BRANCH
CIRCUIT CONDUCTORS SUITABLE FOR 75°C MIN.
WARNING-THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT
OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION
SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
MIN. LAMP COMPARTMENT DIMENSIONS
5.5 inch/139.7mm (DIA) x 5.5 inch/139.7mm (H).
not make or alter any open holes in an enclosure of wiring or
electrical components during kit installation.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
TRDL6 Series
6” Recessed LED Downlight
1 of 2
Minimum distance
between edge of
fixtu re and top of
housing or other
obstruction.
1
2
STEP 1:
Carefully rotate the“Flip Clipsclockwise
until the clips are fully-dep loyed. See
Figure 2.
NOTE: For 5" recessed cans, it is
recommended not to rotate the flip clips
into the ful ly dep loyed position.
STEP 2:
Make sure the POWER IS TURNED OFF at
the source to the recessed can.
STEP 3:
Remove existing trim and bulb, revealing
the existing recessed socket.
STEP 5:
STEP 4:
Screw the fixture Edison base assembly
into the recessed can socket by turni ng
clockwise. See Figure 3.
STEP 6:
Install fixture up in to the recessed housing
firmly until trim ring is flush with the
ceiling. Rotate fixtu re clockwise slightly to
tigh ten fit with ceiling and set in recessed
pilF erusne ,stluser tseb roF .gnisuoh
mirt latem htiw dengila ton eraspilC
clips inside of recessed housing during
installation. See Figure 3 and 4.
3
5.5 inch
(139.7mm)
5.5 inch
(139.7mm)
Flip Clip
1. WARNING
requires knowledge of luminaires electrical systems. If not qua
2. WARNINGTo prevent wiring damage or abrasion, do not expose
wiring to edges of sheet metal or other sharp objects.
3.
4.
WARNING
luminaires that have the construction features and dimensions
shown in the photographs
and/or drawings
where the input rating of
the retrofit kit does not exceed the input rating of the luminaire.
SUITABLE FOR TYPE IC LUMINAIRES.
5. It may be necessary to remove a socket mounting plate for adequate
clearance.
A
B
12. This device is not intended for use with emergency exit fixtures or
emergency exit lights.
Package Contents:
Part Description Quantity
A 6” Retrofit downlight
1
B Edison Socket Adapter
C Field applied label
1
1
Install "Field Applied Label" into the
recessed can.
7.48 inch
(190mm)
Question and Answer IconNeed help?

Do you have a question about the Cree TRDL6 Series and is the answer not in the manual?

Summary

Important Safety Safeguards

General Fire and Electric Shock Warnings

Warns about fire/shock risk and disconnecting power before installation or servicing.

Follow All Safety Instructions

Emphasizes the importance of reading and following all provided safety instructions.

English Installation Instructions

Package Contents Overview

Lists the components included: retrofit downlight, socket adapter, and field applied label.

Recessed Housing Compatibility

Details compatibility with standard 6-inch recessed downlight housings and dimmers.

Installation Steps

Prepare Flip Clips

Instructs to rotate "Flip Clips" clockwise until fully deployed for installation.

Ensure Power is Off

Crucial safety step: ensure power is turned off at the source before proceeding.

Remove Existing Fixture Components

Guide to remove old trim and bulb to expose the recessed socket.

Install Field Applied Label

Instruction to place the provided "Field Applied Label" inside the recessed can.

Screw in Fixture Base

Directs to screw the fixture's Edison base into the socket clockwise.

Mount Fixture Flush

Instructions for mounting the fixture flush with the ceiling, ensuring a secure fit.

Fixture Removal Procedure

Disconnect Power Before Removal

Important note to disconnect power before attempting to remove the fixture module.

Unlock and Detach Fixture

Steps to grip trim, rotate counterclockwise, and pull fixture free from housing.

Compliance and Warnings

FCC Compliance Statement

States equipment complies with FCC Class B digital device limits for interference.