Emissions Tester CCP700/800 Series Hints & Tips
26
Battery failure
The battery should be charging at around 24V if it is anything lower then it will not power
correctly and will need to change. To check the meter reading for the battery:-
Remove Panel end > unplug the green pin plug >
The battery charger should be charging At 30V to check this
Missing Bluetooth Code
Move the mouse cursor to the bottom right to bring the start task bar up
On the taskbar, find the BT icon (may need to click on show hidden icons first (the arrow pointing
up ).
Right click it and select "Add a device"
System should scan for any BT devices in the area (if nding oil temp ensure it is out of holster).
Emissions Tester CCP700/800 Series Hints & Tips
27
Find and select the device you require the ID for
Right click it and select "Properties"
On the next screen select "Bluetooth" Tab at the top
Near the bottom there will be "Unique Identier", this is the BlueTooth ID for the device.
Note this down and enter into the platform config as required.