Turn off the water supply and disconnect it from the water dispenser. Remove the cold tank drain cap to drain
the cold system. When the flow stops, replace the cold tank drain cap.
Reposition the water cooler to complete installation. Connect the waste system if plumbing it in.
Reconnect the water supply line, ensuring the leak detector and shutoff valve device is as near to the
water supply point as possible, in correct sequence with any pressure reducing valve (also
recommended for excellence and safety in installations).
Draw at least 3 litres of water from each faucet to dispel all air from the system; taking care - as
before - not to trip the leak detector and shutoff valve device.
Ensure that the available power supply matches the cooler's voltage specifications indicated on the
nameplate label (located at the rear). Plug power supply cord into receptacle. Please ensure that
cooler is set up so as access to the power outlet and plug is unobstructed.
Note: To provide additional protection from the risk of shock, this unit MUST be connected to a
ground fault circuit interrupter (GFCI) outlet at all times. Use of an extension cord will void any
warranties.
Allow the water cooler to reach normal operating temperature.
Dry off any water spillages. Record the date of installation, devices installed and serial number of
the water cooler in the appropriate document(s). A photograph of the final installation is useful for
possible future insurance purposes.
While we manufacture our products in the most hygienic/sanitary way possible, we do
recommend cleaning and sanitization prior to first usage.
GENERAL OPERATION
To draw cold water, depress either the BUBBLER button or GOOSENECK FAUCET handle
(Optional)
Position water cooler away from the wall (or any obstacles) in minimum of from the 4 inches (10cm)
back of the unit to ensure proper ventilation.
CAUTION! ALWAYS DRAIN WATER COMPLETELY
BEFORE SHIPPING OR STORING THE WATER COOLER
Gooseneck Faucet
Bubbler
Water Inlet
Cold Tank Drain
Waste Outlet
Power Cord
Front Panel
Body
Waste Inlet
Back ViewMain View
Services required: Water Inlet: 1 " John guest fitting./4
Water pressures: Minimum 20 PSI (0.138MPa)
Maximum 80 PSI (0.552MPa)
(Usage of a pressure regulator is advised anytime that pressure can reach higher than 80 PSI (0.552MPa)
or if unit is installed above the ground floor.) Waste outlet: 1 " (40mm) multi-fit connection.
1
/