Page 20 40 Series Granulators
3-4 Electrical Service Connections
Carefully check the diagrams packed with the machine. All
internal wiring has been done at the factory and safety
interlocks have been verified for proper functioning before
shipment. It is only necessary to connect the electrical
power source to the machine at the control enclosure.
WARNING!
The customer’s disconnecting means and branch circuit protection must also
be in compliance with the National Electric Code and all Local Codes.
3-5 High Amperage Readings
NOTE: Make sure the granulator is not drawing excessive
amperage.
1. Check appropriate amperage as listed on the motor
nameplate.
2. Measure amperage with ammeter by connecting
ammeter to incoming power feed wires. Make sure
machine is not drawing more than amperage listed on
the nameplate. The amperage will change according to
motor size.
3. If amperage exceeds the amount listed on nameplate,
check the following:
Sharpness of knives
Quoted feed rate of granulator