4 — DEVICE PARAMETER OBJECTS
Curtis 3140 Manual – Nov. 2017
pg. 10
CAN Index Sub-Index Name Length
(Bytes)
Read/ Write NVM
3
Default Value
0x3005 0x00 Backlight percent (0 – 100%) 1 R/W N 0
0x3010 0x00 Hourmeter value (internal) 4 R Y
0x3010 0x01 Hourmeter enable (0 =
disabled, 1 = enabled)
1 R/W N 0 (disabled)
0x3010 0x02 Hourmeter reset (non-zero
value will reset)
1 R/W N 0
0x3020 0x00 BDI_percent (0 – 100%) 1 R Y
0x3020 0x01 BDI_prescaler 2 R Y
0x3020 0x02 BDI_discharge_full
(mV per cell)
2 R/W Y 2050
0x3020 0x03 BDI_discharge_empty
(mV per cell)
2 R/W Y 1750
0x3020 0x04 BDI_CTR_full (mV per cell) 2 R/W Y 2350
0x3020 0x05 BDI_CTR_empty (mV per cell) 2 R/W Y 2100
0x3020 0x06 BDI_OCR (mV per cell) 2 R/W Y 2090
0x3020 0x07 BDI_integration_time 1 R/W Y 30 (minutes)
0x3020 0x08 B+_nominal (volts, 24, 36, 48) 1 R/W Y 24
0x3030 0x00 Bplus_mV 2 R N B+ in millivolts
0x3050 0x00 rmware_part_number 4 R Y 1769039001
0x3149 0x00 can_pdo_timeout_period 2 R/W Y 0x07D0 = 2000
ms
0x3200 0x00 P_User_1 4 R/W Y
0x3201 0x00 P_User_2 4 R/W Y
0x3202 0x00 P_User_3 4 R/W Y
0x3203 0x00 P_User_4 4 R/W Y
0x3204 0x00 P_User_5 4 R/W Y
0x3205 0x00 P_User_6 4 R/W Y
0x3206 0x00 P_User_7 4 R/W Y
0x3207 0x00 P_User_8 4 R/W Y
0x3208 0x00 P_User_9 4 R/W Y
0x3209 0x00 P_User_10 4 R/W Y
3
Non-Volatile Memory: these values are recalled upon power up.
Table 2: CAN Object Dictionary continued