PROGRAMMING GUIDE PG1
(130(3"..*/((6*%&ø H
Brew Settings Menu (cont.)
Pulse Brew - TFMFDUTUIFQVMTFCSFXQBUUFSO1SF*OGVTJPONVTUCFPGGUPBDDFTTUIFGBDUPSZEFGBVMUTFUUJOH
<(PVSNFU45%TFUUJOH>JT$5IFQVMTFCSFXQBUUFSOTFMFDUFEiUVOFTwPSDIBOHFTUIFnBWPSPGUIFDPGGFF*G
FOFSHZTBWFSNPEFJTPOBGUFSQSFTTJOHUIFCSFXCVUUPOUIFCSFXDZDMFXJMMTUBSUXIFOUIFXBUFSJOUIFUBOL
reaches brewing temperature.
Pulse Brew Guidelines
• 'JMUFSQBDLUZQFDPGGFFTUZQJDBMMZFYUSBDUCFUUFSXJUIUIF"BOE#QVMTFTFUUJOH
• %FDBGGFJOBUFEDPGGFFTUZQJDBMMZFYUSBDUCFUUFSXJUIUIF#QVMTFTFUUJOH
• )JHIZJFMEDPGGFFTUZQJDBMMZFYUSBDUCFUUFSXJUIUIF$QVMTFTFUUJOH0GDPVSTFBOZPGUIF"#PS$
TFUUJOHTNBZCFVTFEUPTVJUZPVSUBTUFQSPmMF
• Settings D and E are manual pulse counts.
By-Pass (G4TP1 and G4TPX1 series) - IFMQTDPOUSPMFYUSBDUJPOGPSMBSHFSCSFXT5IFGBDUPSZEFGBVMU
TFUUJOHT<(PVSNFU45%>BSF-"3(&BOE4."--#ZQBTTSFEVDFTDPOUBDUUJNFUPBWPJEFYUSBDUJPOPG
VOEFTJSBCMFCJUUFSBOEIBSTInBWPSDPNQPVOET5IFTFUUJOHSBOHFJTUP
By-Pass (all models except G4TP1 and G4TPX1 series) - IFMQTDPOUSPMFYUSBDUJPOGPSMBSHFSCSFXT5IF
GBDUPSZEFGBVMUTFUUJOHT<(PVSNFU45%>BSF-"3(&.&%*6.BOE4."--#ZQBTTSFEVDFT
DPOUBDUUJNFUPBWPJEFYUSBDUJPOPGCJUUFSBOEIBSTInBWPSDPNQPVOET5IFTFUUJOHSBOHFJTUP
Drip-out Mode - TFUTUIFESJQPVUNPEFUJNFS"GUFSXBUFSTUPQTnPXJOHJUBMMPXTBEEJUJPOBMUJNFGPSUIFXBUFS
UPESBJOGSPNUIFCSFXCBTLFUCFGPSFi#SFXJOHwEJTBQQFBSTGSPNUIFEJTQMBZ5IFGBDUPSZEFGBVMUTFUUJOHJTUXP
NJOVUFT5IJTGFBUVSFSFEVDFTUIFDIBODFUIBUUIFCSFXCBTLFUXJMMCFSFNPWFEUPPFBSMZ5IFTFUUJOHSBOHFJT
TFDPOETUPNJOVUFT
Model Select Menu
Batch Size - 5IFNPEFMOVNCFSBOETJOHMFUXJOTFUUJOHTBSFTFUBUUIFGBDUPSZBOETIPVMESFNBJOTFUUPNBUDI
UIFNPEFMOVNCFSMBCFMBGmYFEUPUIFVOJU)PXFWFSUIJTTVCNFOVDBOCFVTFECZUIFFOEVTFSUPTFMFDUUIF
OVNCFSPGCSFXCVUUPOTCBUDITJ[FUIBUBQQFBSPOUIFEJTQMBZ6QPOFOUFSJOHUIF.PEFM4FMFDUNFOVTFMFDU
UIFDPSSFDUNPEFMOVNCFSBOETJOHMFUXJOTFUUJOHUIFOTFMFDUUIFCBUDITJ[F
Setting Description
A Toward the beginning of brew cycle: 4 cycles of 10 seconds on and 10 seconds off, then on until end of brew cycle.
B
Starts towards ends of brew cycle. 4 cycles of 10 seconds off and 4 cycles of 10 seconds on. Ends when brew
cycle ends.
C Starts at beginning of brew cycle. 5 cycles of 25 seconds on and 20 seconds off, then on until end of brew cycle.
D
Manually set. Starts at beginning of brew cycle. Number of pulses is adjustable from 1 to 12. Pulse on time and off
time are both adjustable from 5 to 150 seconds.
E
Manually set. Starts at beginning of brew cycle. Number of pulses is adjustable from 1 to 12. Pulse on time and off
time are both adjustable from 1 to 150 seconds.
Batch Size (Brew Buttons Displayed)
TP1 and TPX1 All other models
Three Batches NA
Large
Medium
Small
Two Batches
Large
Small
Large
Small
One Batch Large Large