Thermostat Adjustment
The thermostat is factory set to cut off at 200ºF. If necessary, adjust it as follows:
1 Turn the main power switch OFF.
2 Rotate the thermostat knob to the right, to the BOIL position.
3 Pull off the knob.
4 In the thermostat stem, locate the tiny adjustment screw.
5 Using a small screwdriver, adjust the temperature up or
down. Turning the screw ¼ turn to the left will increase the
temperature about 20°F. Turning the screw ¼ turn to the
right will decrease the temperature by 20°F.
6 Replace the knob.
7 To determine the temperature setting, turn the urn power
switch ON, insert a thermometer probe into the water after
about 60 minutes and re-adjust as necessary according to
the steps above.