CyberData Corporation
3 Justin Court, Monterey, CA 93940
www.cyberdata.net
P 831.373.2601 | F 831.373.4193
RING CENTRAL CONFIGURATION GUIDE: SIP PAGING ADAPTER (SPA)
Doc. 931050B Page 36
Configure SIP Parameters
If you are configuring through the web interface, use the following steps to login to the web
interface of your SPA and register the paging extension with RingCentral.
1. Click Launch Browser from the CyberData Discovery Utility or point your browser
to the CyberData device’s IP address to access the Home Page of the web interface.
2. Enter the web login credentials when prompted and click the Log In button.
3. On the Home Page, click SIP Config on the left-hand side of your screen to access the
SIP Configuration page.
4. Enter the provisioning information from the Assisted Generic IP Phone
Provisioning popup window. Use Table 6-1 to enter RingCentral SIP values into the
proper CyberData SIP fields.
Note the Local SIP Port is set to 5060 on default and is used by the SPA as its source port
for the paging extension configured on this page.
5. Set the Re-registration Interval (in seconds) to 30 seconds.
6. Set the Keep Alive Period to 0.
7. Enable Force Codec Selection and use PCMU.
8. Click Save and Reboot to store changes.