EasyManua.ls Logo

CyClone SC322 - Troubleshooting

CyClone SC322
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38 Cyclone Canopy Installation - English
TROUBLESHOOTING
ISSUE CAUSE SOLUTION
Unit doesn’t work aer
installation.
1. e power source is not turned ON. 1. Ensure power is ON for the circuit breaker and
unit.
2. e power line and the cable locking connector
are not connected properly.
2. Check the power connection with the unit is
connected properly.
3. e switch button seized. 3. Loosen the switch mounting screws from back
of the switch.
4. e control panel and motherboard wirings are
disconnected.
4. Make sure wiring between the control panel and
motherboard are connected properly.
5. e control panel or motherboard is defective . 5. Change the control panel or motherboard
board.
Light indicates power
ON but motor doesn’t
turn.
1. e motor is defective, possibly seized. 1. Change the motor. Servicing may be required.
2. e switch button seized.. 2. Loosen the switch mounting screws from back
of the switch.
3. e control panel or motherboard is defective. 3. Change defective part. Servicing may be
required.
e unit vibrates. 1. e motor is not secured. 1. Tighten the motor in place.
2. Damaged blower wheel. 2. Replace the blower wheel. Servicing may be
required.
3. e hood is not secured in place. 3. Check the installation of the hood.
4. Venting duct too small or blockage in the duct
opening or ductwork.
4. Check the venting duct and the wall cap or roof
cap.
Motor works but lights
do not turn on.
1. Defective halogen bulb. 1. Change the halogen bulb.
2. e light bulb is loose. 2. Tighten the light bulb.
3. e wire connector for lights is loose. 3. Call for assistance.
4. Defective light transformer. 4. Change transformer. Servicing may be required.
e hood is not venting
out properly.
1. e hood might be hanging too high from the
cook top.
1. Adjust the distance between the cook top and
the bottom of the hood within 28” - 36” above
the range.
2. Blockage in the duct opening or ductwork. 2. Remove all the blocking from the duct work or
duct opening.
3. Using the wrong size of ducting. 3. Use at least 6” duct work.
For additional service inquiries, contact Cyclone servicing department at 1-888-293-5662 or Service@CycloneRangeHoods.com