21
RS485 connection
To use RS485 communication directly from a computer, a master unit must be configured to receive
RS485. You must have a suitable RS485 port on your computer, or a converter connected to the serial port
in use. This configuration is shown below, along with the required unit setup.
The adapter is available in a kit, which includes an RJ-45 adapter, the XLR to 9-pin adapter, and the
converter itself. This complete kit is part number INT-485.
If you need to make up one of the XLR to 9-pin adapters, the pin-out is:
XLR D-type
1 1
2 3
3 8
Additional DSP-2060As
may be set up as slaves
with incremental
ID numbers
as necessary...
OR
via wireless with
Walkabout Pack II KIT
(Please see your manual
available from our website)
DSP-2060A
Interface Sub Menu
Mode = RS485 Mode
SERIAL SPEED = 115200
Stop MIDI Prog Chng Yes
Remote ID Number = 1
RS232 to RS485
CONVERTER KIT
Part Number
INT-485
DSP-2060A
User’s Manual