12
DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
12
Programmable output 3
No. Name Range Factory Setting
o300 Function of output 3 0 - 4 1
0 Disabled
1 Position indication/Movement/Warning. Signal as congured in o310 – o322
2 Presence detection/Direction sensing. Signal as congured in o391
3 Lock
4 Alarm output Signal as congured in o330 – o342
o310 Open position 0 - 1 1
0 Disabled
1 Constant signal
o311 Mid position 0 - 1 0
0 Disabled
1 Constant signal
o312 Closed position 0 - 1 0
0 Disabled
1 Constant signal
o313 Movement 0 - 4 4
0 Disabled
1 Constant signal in the opening movement
2 Constant signal in the closing movement
3 Constant signal in the opening and closing movement
4 No signal during movement, used in combination with o310, o311 and o312.
o314 Delayed switch-o Switch o aer the specied time For
example to switch o lighting a specied time aer closing
0.00-9.59 minutes 0.00
o320 Warning time before start 0.00-9.59 minutes 0.00
o321 Warning function in combination with o320 1 - 4 2
1 Constant signal before automatic closing
2 Constant signal before park and automatic closing
3 Constant signal before close signal, park and automatic closing
4 Constant signal before all signals
o322 Function during warning time 1 - 2 1
1 Output signal disabled during warning in other output
2 Signal as congured in o310-o313