Page #5 background imageLoading...
Page #5 background image
4
17
Temperature range for use
0 ~ +60°C
18
Effect by temperature change
Zero drift : within ± 1 µstrain/°C
Sensitivity change: ± 0.03% F.S/°C
19
Effect by electric power change (About ± 10% change in supply voltage)
Zero drift: within ± 0.05% F.S
Sensitivity change: within ± 0.05% F.S
20
MONITOR : Digital Voltage Display
Over 10V will be displayed in 10.00 (increased or decreased in each 0.01)
Less 10V will be displayed in 0.000 (increased or decreased in each 0.001)
Voltage on OUT1 will be displayed in Digital.
21
Supply Voltage
AC100/220V ± 10% 60Hz
22
External Size and Weight
128.4 (H) × 43.2 (W) × 198 (D) mm
1000g
23
OPTION
Output: OUT1 ± 100mA output

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the dacell AM-1000 and is the answer not in the manual?

dacell AM-1000 Specifications

General IconGeneral
Branddacell
ModelAM-1000
CategoryAmplifier
LanguageEnglish