1-3. Data Protocol (Data Format 1.Total 18byte)
,
,
K g CR LF
Header1 Header2 Data(8) unit
Header 1
- OL : OVER LOAD or UNDER LOAD
- ST : Weight Stable
- US : Weight Unstable
Header 2
- NT : Net Weight (Without TARE Weight)
- GS : Gross Weight (With TARE Weight)
DATA(8) Symbol(1) , Decimal Point(1) , Weight (6) = total 8BYTE, like +000.190
- 2B(H): "+"PLUS
- 2D(H): "-"MINUS
- 2O(H): " "SPACE
- 2E(H): "."Decimal point
UNIT
- Kg , g