EasyManua.ls Logo

dacell DN501A - 3. SPECIFICATION; 3-1. Analog Input & A;D Conversion; 3-2. Digital Part

dacell DN501A
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. SPECIFICATION
3-1. Analog Input & A/D Conversion
Input Sensitivity
0.45 / Digit
Load Cell Excitation
DC 10V ( - 5V ~ + 5V )
Max. Signal Input Voltage
Max.32mV
Temperature Coefficient
[Zero] ±20PPM/
[Span] ±20PPM/
Input Noise
±0.6 P.P
Input Impedance
Over 10
A/D Conversion Method
Sigma-Delta
A/D Resolution(Internal)
260,000 Count(18bit)
A/D Sampling Rate
Max. 80times / Sec
Non-Linearity
0.01% FS
Display Resolution(External)
1/30,000
3-2. Digital Part
Display Parts Specification
Display
Main Display
7Segments, 6digits 1.0 inch Red color FND
Size : 25.4(H) ×14.4(W)mm
Min. Division
×1, ×2, ×5, ×10, ×20, ×50
Max. display value +999,950
Under Zero value "-" (Minus display)
Status lamp
Steady, Zero, Print,
Gross, Auto, g, kg, ton,
Tare, RTxD
Green color Condition display Lamp (10pcs)
K e y
Number, Function Key Number Key, Function (12pcs)
4 / 41