The potenometer (right hand rotary dial) is used for
both manual and automac operaons of the control. The
minutes for the automac side of the control are on the
outer labeling ring (5 minutes full clockwise, 30 minutes
full counterclockwise). On manual, the percent of speed is
from the very slowest (0% - full stop) full counterclockwise
to maximum speed (100%) full clockwise.
The on/o switch (circuit breaker included) is mounted in
the control le side panel.
A. Power Source-The control operates only on 110-120 volt
A.C. Plug the power cord into an appropriate grounded
outlet and connect the yellow twist-lock connector to
the connector on the extractor motor. The output of
this unit is 0 - 90 volts D.C. and must be used with 0 - 90
volt D.C. motors up to and including 1 H.P.
B. Power Switch-Turn the power switch on” and note
that two lights are lit on the “visual display.” This power
switch incorporates a circuit breaker to protect the con-
trol from current overload. Should this circuit breaker
open, merely reset the power on switch to reset the
breaker. This switch should be shut o at the end of
each extracng day, and the start-stop switches may be
used between extractor loads.
C. Operator Control Center-The operator may select
manual or automac operaon. To make the selecon,
press the switch for the operaon desired. On automat-
ic (auto start) the light on the le of the visual display
will ash. On manual, the light on the right of the visual
display lights and stays lit while running on manual.
1. Manual Operaon-The reel speed on manual is con-
trolled by the dial on the upper right of the control. For
Manual Operaon, read the inside labeling. The 0-100
indicates percent of speed. 100% is approximately 280
rpm; therefore, 50% is approximately 140 rpm. To use
manual, merely set the speed desired and press manual
start. The extractor will advance to the set speed and
remain there. This speed may be varied at any me dur-
ing manual operaon by turning the dial.
2. Automac Operaon-Your cycle me may be varied
from 5-30 minutes. Automac operaon is obtained by
pressing auto start. The me of extractor operaon is
selected by the operator. To use the automac cycle, set
the complete extracng me desired using the rotary
dial. Read the outside scale (5 minutes full clockwise
to 30 minutes full counterclockwise) then press auto
start. The reel will begin rotang slowly and gradually
increase speed unl full speed is reached. This occurs
at 75% of the set cycle me. The reel connues at full
speed for the remainder of the cycle and automacally
shuts o. The manual brake may then be used to stop
the reel.
An internal selector switch allows the owner to select a
variety of automac cycles. The extractor can be precisely
controlled to allow for a variety of extracng condions
(temperature—moisture level—type of honey—condion of
frames). Your control comes preset for “average’ operang
condions for your size extractor and will be the proper set-
ng for 80 - 95% of extracng condions. (This switch should
be changed for special condions only). However, for your
parcular extracng job, a dierent operaon characterisc
may be desired.
To select a dierent operang characterisc, remove the six
phillips head screws holding the cover in place. Be sure the
control is unplugged from its Power Source. Li the boom
edge of the cover up turning it completely upside down as if
using the top of the cover as a hinge. In the upper le of the
upside down cover, you’ll see a small selector switch with a
center arrow and screw driver slot. Around the outer edge,
the leers A-F and the numbers 0-9 appear. The arrow will
be poinng at one of these characters. By referring to the
charts below, you may select an operang characterisc just
right for your extracng condions. For assistance, call your
local Dadant Branch Manager.
For “average” operaon, the selector switch is set on “B” for
a 30-frame, on “E” for a 60-frame, and on “D” for a Honey
Master. (The larger the extractor, the slower the acceleraon
and starng and ending speeds).

