NS4710 / NS6010 / NS4710H / NS5310H / NS6010H
4
-
12
PTO SHIELD AND SHAFT CAP
te7O434a
(1) PTO Shield (2) PTO Shaft Cap
You should keep the PTO Shield in
place at all times and remember to
replace the cap when the PTO shaft
is not in use.
DPF REGENERATION SWITCH
(1) DPF Regeneration Switch
(A) Activation (B) Deactivation
ACTIVATION (UPPER PORTION OF
SWITCH)
Perform the following instructions
when the regeneration warning lamp
comes on: (see page 4-18.)
1.Parkthetractoronaatsurface.
2. Idle the engine.
3. Depress the brake pedals and
stop the vehicle.
4. Put all shift levers into the neutral
position.
5. Run the engine for 3 to 4 minutes.
Then, press the activation portion
of the regeneration switch for ap-
prox. 2 seconds.
DEACTIVATION (LOWER PORTION
OF SWITCH)
Do not press the deactivation portion
of the switch while the regeneration
process is activated.
However, the switch can be set to
the deactivation position to stop the
regeneration process in emergency.
NOTE
• The illumination timing of the
regeneration process lamp may
differ depending on the DPF
temperature.
6. The regeneration warning lamp
goes off and the regeneration pro-
cess lamp blinks.
Before resuming your work, wait
for approx. 30 to 40 minutes until the
regeneration process is completed.