How to use (DBR-S21)
How to use Heating water/Room temperature
By pressing Heating water temperature selection button, you can choose either heating water or
room temperature. The Set temperature display and Heating water/Room temperature display
flicker for about 10 seconds after which your choise is confirmed.
When using room temperature setting, depending on the location of the room controller, temperature
deviation may occur. To optimize temperature control, use Heating water temperature setting.
Notes
This boiler uses a propotional control method designed to adjust the flame according to the difference
between the set temperature and the current temperature.
The table below shows the temperature differences which will cause either the boiler flame to be ignited,
or extinguished.
The temperature when
the boiler flame is ignited
The temperature when
the boiler flame is extinguished
When using Room
temperature setting
When using Heating water
temperature setting
1 C lower than the set
temperature
12 ~ 18 C lower than the
set temperature
Any temperature higher
than the set temperature
7 C higher than the
set temperature
o
o
o
Press Heating water
temperature selection
button.
18
C MH
55/15
45
/5
65
/25
80
/40 C
O
75
/35
C MH
55/15
45
/5
65
/25
80
/40 C
O
75
/35