DGB-100MSC
DGB-130MSC
DGB-160MSC DGB-200MSC
Specifications
Type
Model
Item
Instantaneous Gas fired boiler
Use
Central heating / Domestic hot water
Gas control type Proportional gas control system
Heating circulation type
Hermetic tank (Closed) type
Heating output (max.)
11.6kW
(10,000kcal/h)
15.1kW
(13,000kcal/h)
18.6kW
(16,000kcal/h)
23.3kW
(20,000kcal/h)
Range of Heating output
7.0kW~11.6kW
10.5kW~15.1kW 10.5kW~18.6kW 10.5kW~23.3kW
Hot water output (max.)
18.6kW
(16,000kcal/h)
18.6kW
(16,000kcal/h)
23.3kW
(20,000kcal/h)
Range of Hot water output
7.0kW~18.6kW 10.5kW~18.6kW 10.5kW~23.3kW
Hot water supply
Increaced dT25
Increaced dT40
10.7 l/min
6.7 l/min
13.3 l/min
8.3 l/min
Min. water pressure on hot water 20kPa (0.2bar)
Range of gas pressure
1~2.5kPa (10~25mbar)
Gas input
(max.)
Heating
Hot
water
LPG
LNG
LPG
LNG
12.7kW(1.0kg/h)
12.7kW(1.14m /h)
3
16.8kW(1.33kg/h) 21.1kW(1.67kg/h)
26.5kW(2.1kg/h)
16.8kW(1.52m /h)
21.1kW(1.9m /h) 26.5kW(2.4m /h)
3 3 3
Heating efficiency
21.1kW(1.67kg/h)
21.1kW(1.9m /h)
3
26.5kW(2.1kg/h)
26.5kW(2.4m /h)
3
Power supply
AC 220V 50Hz
Electrical input
110W
Size (WxHxD)
490 x 626 x 242 mm
Weight
27kg
Duct diameter
Air inlet 110mm / Gas flue 80mm
Piping
Gas
Water in/
Hot water out
Heating water in/
Heating water out
Safety Devices
Anti-freezing device, Flame detector, Burner Safety device, Extinction safety device,
Pressure relief device, Safety device for re-ignition, Fan malfunction detection device,
Circulation pump stick guard device, Boiling guard safety device, Replenish device,
Overheating guard device, Gas leak detector(optional)
Accessories
Room controller, Installation plate, chimney(optional)
91%
91% 91% 91%
100W 105W 105W
40
26kg