Points to check before using the boiler
Warning!
Check the power supply.
- This boiler is for AC220V only.
Use a power transformer if necessary (in the area of 110V).
Using current other than AC may cause electric shock
or fire.
AC220V
Check if the boiler is properly installed.
- The location chosen for the boiler must permit the provision of a satisfactory flue termination.
The location must also provide adequate space for servicing and air circulation around the boiler.
- Installation must be carried our solely by qualified technicians.
- Verify that the boiler vent discharge and air intake areas are clean and free of obstructions.
- The boiler must be mounted on a flat, vertical wall, which must be sufficiently robust to take the
weight of the boiler.
- The boiler may be installed on a combustible wall, subject to the requirements of the Local Authorities
and Building Regulations.
Warning!
Check flue gas venting system.
- Visually inspect entire flue gas venting system for blockage, deterioration or leakage.
- A gas leak may lead to gas poisoning.
Never leave flammable materials in the immediate
vicinity of the boiler.
- Flammable materials may result in fire and
explosion.
thinner
gasoline
matches
Check if the boiler and heat radiator units are filled with water.
- After plugged in, if “E1” appears on the display of the room controller, the boiler is empty.
- If the display shows “E1”, replenish the boiler with water.
Plug in
* If there is no water in the boiler,
“E1” appears on the display of the
room controller.
Open the replenish valve,
and the boiler will be
replenished with water.
* When the boiler is replenised
with water, “E1” on the display
disappears.
Open gas valve