DSB-125L DSB-125LH DSB-185L DSB-185LH
Ph-V-Hz 220-240V~,50Hz 220-240V~,50Hz 220-240V~,50Hz 220-240V~,50Hz
Capacit
Btu/h
12000 12000
18000 18000
Input W
1350 1350 1960 1960
Rated current A
6.0 6.0
9.4 9.4
EER Btu/w.h, w/w
8.9,2.6 8.9,2.6 9.2,2.7 9.2,2.7
Capacity Btu/h
___________
14000 / 19000
Input W
___________ 1350
/1856
Rated current A
___________ 6.0
/8.4
COP W/W 3.0 / 3.0
L/h 1.5 1.5 1.9
W
1700 1700
2200 2130
A 8.0 8.0 10.2 10.4
A
33 33 42 42
Model
PH225X2C-4FT PH225X2C-4FT PH290X2C-4FT1 PH290X2C-4FT1
T
Btu/h 13197/13299 13197/13299 17435 17435
In
ut W 1250/1285 1250/1285 1670 1670
Rated current
5.7/5.5 5.7/5.5 8.0 8.0
Locked rotor Am
29.9/33 29.9/33 41.2 41.2
Thermal
rotector UP3RE0591-T56 UP3RE0591-T56 Internal Internal
Ca
acitor uF 1.5uF/450V 1.5uF/450V
S
r/min 1180/1000/850 1180/1000/850 1180/1080/800 1180/1080/800
m3/h
580/500/420 580/500/420 800/730/600 800/730/600
dB(A)
37/32/28 37/32/28
42/40/38 42/40/38
Dimension
mm
790x265x195 790x265x195
920×292×225 920×292×225
Packin
mm
875×375×285 875×375×285
1015X370X295 1015X370X295
Net/Gross wei
ht Kg 9.0/11.0 9.0/11.0 13/15 13/15
Model YDK24-6 YDK24-6 YDK36-6 YDK36-6
Brand Welling Welling WELLING WELLING
Input W 85 85 96 96
Capacitor uF
2.5
μ
F/450V 2.5
μ
F/450V 2.5
μ
F/450V 2.5
μ
F/450V
Speed r/min 900 900 900 900
m3/h 2000 2000 1800 1800
dB(A)
54 54
56 56
Dimension
mm
780×540×250 780×540×250
780X540X250 780X540X250
Packin
W*H*D mm 910x575x335 910x575x335 910x575x335 910x575x335
Net/Gross wei
ht Kg
34/37 34/37 37/40 40/42.5
g
850 900
1130 1400
MPa
2.6 2.6 2.6 2.6
Liquid side/ Gas
mm(inch)
Ф
6.35/
φ
12.7
Ф
6.35/
φ
12.7
Ф
6.35/
φ
12.7
Ф
6.35/
φ
12.7
Max. refri
m10101515
Max. difference i
m5 5 8 8
No No No No
16A 16A No No
Electronic control Electronic control Electronic control Electronic control
℃
17-30 17-30 17-30 17-30
℃
18-45 -7 - 45 17-45 -7 - 45
m2 18-26 18-26 30-40 30-40
set 108/226/266 108/226/266 100/210/245 100/210/245
Model
Power supply
Cooling
Heating
Moisture Removal
Max. input consumption
Max. current
Starting current
Compressor
Indoor fan motor
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Indoor unit
Outdoor fan moto
Outdoor air flow
Outdoor noise level
Outdoor unit
Refrigerant type R22(R407C)
Design pressure
Refrigerant piping
Ambient temp
Application area
Qty’per 20’ /40’ /40'HQ
Connection wiring
Plug type
Thermostat type
Operation temp
★1 The noise date is base on hemi-anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient
condition.