EasyManua.ls Logo

Daewoo FRS-2021 - Power Failure Troubleshooting

Daewoo FRS-2021
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. Power failure of refrigerator (F/R lights OFF / F-PCB power OFF)
Change the fuse
(AC 250V 15A)
(The fuse is in the left of machine room
of refrigerator back.)
Failure Checkup & Troubleshooting
Start
Power cord or fuse is
disconnected ?
1
st
power of SMPS is ON ?
Main PCB Fuse is
disconnected ?
12V,16V,5V on M-PCB is
OK ?
Wire connection of F-PCB
is OK ?
Check power cord connection in
machine room and to CN1 of M-PCB.
Change F-PCB AS.
Change Main-PCB.
Change the fuse.
(AC 250V 3.15A)
(The fuse is on the M-PCB.)
Checkup and connect F-PCB wires.
Y
N
N
Y
N
Y
Y
N
Y
N
Note) Change of F-PCB
1) Insert a flat tip driver into the left down groove of panel frame and snap it out smoothly.
2) Remove housing from F-PCB and screws on the board to change for a new one.
* Assembling is the reverse order of disassembling.
Page 3