36
The starting wattage of some appliances are can be higher than the operating watts. Please read the
labels of the electric equipment for reference. The total power of the loads should not exceed the
rated power of the generator.
11. MAINTENANCE
Regular maintenance is the best guarantee of safe, economical and fault-free operation, and can also
contributes to environmental protection.
Maintenance schedule is as follows- Please carry out the recommended maintenance at the earlier of
the stated hours or elapsed time.
(1) Maintenance should be conducted more frequently if the unit is used in dusty conditions.
(2) Maintenance should be conducted by an authorized Daewoo generator dealer (to find one see tpeaustra-
lia.com.au/dealers).
Replace the engine oil
SCHEDULE FOR
REGULAR MAINTENANCE
PER
USE
EVERY 20
HOURS OR IN
THE FIRST
MONTH OF
INITIAL USE (3)
EVERY 50
HOURS OR
EVERY 3
MONTHS (3)
EVERY
100 HOURS
OR EVERY 6
MONTHS
(3)
EVERY 300
HOURS OR
EVERY YEAR
(3)
Engine oil
Inspect the
oil level
Replace
Air filter
Inspect
Clean
(1)
Fuel strainer bowl
Clean
Spark plug
Clean
Replace
Valve clearance
Readjust
(2)
Cylinder head
Wash
Every 300 hours (2)
Fuel tank and
strainer
Wash
Every 2 years (2)
Oil tube
Replace
Every 2 years (2)
Required oil level
Oil dips�ck
Oil dipstick
Oil drain plug
O il drain plug