Alarm Control Panel Installer Manual
39
RESTART: This option turns off and immediately re-arms the control panel. This function can be
useful to perform PATROL ROUND to disarm one or more areas getting automatic re-arm after
the programmed exit time area.
TIMER OFF: This option is not subject to TRIGGER, DELAY OR FORCED and works only in the
table step from N.C. to N.O. status. When opened, it locks arming operations subject to a TMER
which are programmed for the AREAS to which it is associated. In practice, it functions as a key to
lock/unlock ON/OFF TIMERS active on the AREAS.
IN AND ZONES 1.25
You can set maximum eight IN AND ZONES couples. For each IN AND ZONES, you can combine two
zones and establish the alarm linkage between them.
After entering the Installer Menu, press and to scroll up and down until you reach the IN Step 1
AND ZONES menu. See Figure 1-21.
IN AND ZONES Figure 1-21
Press to enter the programming mode. Step 2
Press and to select the IN AND ZONE that you want to configure, and then press Step 3
.
By pressing + 2, you can enter the EDITING mode for changing the description of IN AND
ZONE.
Configure the settings. See Table 1-14. Step 4
Press and to alter the options. Press to confirm the setting and move to the next
submenu.
Table 1-14 IN AND ZONE programming settings