Alarm Control Panel Installer Manual
45
Submenu
Setting
If only one area has been assigned, this parameter has no value.
POLAR
The choice of the output polarity determines the at rest status of the output
itself. In practice, the output can be placed in HIHG or LOW electrical
status (high status gets more security)
DIRECT
REVERSE
If you press to confirm the option, you will exit and the output will
immediately take on the selected polarity.
LINK Outputs
LINK outputs can be commanded by the User or by association with zone inputs. In practice, outputs are
activated following the status of specific (wired or wireless) zones or through a direct manual command and
can be programmed as Toggle or Pulse.
The outputs can also be associated with a maximum of 4 (Start/Stop) TIMERS which can limit the outputs
operations to specific time periods during the week.
Table 1-18 Link outputs programming
Submenu
Setting
LINK ACT DUR
Set the activation time of the output (minutes/seconds).
LINK ACT DLY
Set an eventual delay time before output starts (minutes/seconds).
TRIGGER
This parameter is shown only if the delay is programmed in impulse mode.
SINGLE: During its impulse activation, a further command does not
restart the impulse time. In this case, the LINK can reactivate only
after the entire impulse duration has elapsed.
CONTINUOUS: During its impulse activation, when another
command is received, the impulse time restarts from the beginning
time.
In practice, TRIGGER auto-regenerates at each new impulse until it
comes to the end of the set time.
TIMER1/TIMER2/
TIMER3/TIMER4
Follows the setting of Timers (00 to 16).
The outputs can also be associated with a maximum of 4 (Start/Stop)
TIMERS which can limit the outputs operation to specific time periods
during the week.
Press and or directly press the value + to alter the timer
to be set. After making the selection, press to move to the next field,
and after setting the fourth timer, press to move to the Polar screen.