Alarm Control Panel Installer Manual
49
Press to return to the AREAS selection menu. Step 5
Then you can continue with programming other AREAS, or press to return to the AREAS
menu from where you can press and to move to the next menu or press to exit
from the Installer Menu.
SYSTEM FUNCTIONS 1.28
After entering the Installer Menu, press and to scroll up and down until you reach the Step 1
SYSTEM FUNCTIONS menu. See Figure 1-25.
System functions Figure 1-25
Press to enter the programming mode. Step 2
Configure the settings. See Table 1-22. Step 3
Press and to alter the options. Press to confirm the setting and move to the next
submenu.
The two numeric fields 000.00 represent minutes and seconds.
Table 1-22 System functions settings
Maximum of alarm cycles.
Set the maximum number of alarms that the control panel can generate
during an arming cycle. This count is the total of the maximum number of
alarm cycles for all the control panel zones. 000 represents that there is no
limit.
Max system alarm cycles.
Set the maximum number of alarms generated during one alarm cycle by
the control panel tamper, siren tamper, module tamper, bus alarm (if
enabled), wireless alarm (if enabled), and supervision alarm (if enabled).
000 represents that there is no limit.
Set which area(s) the alarm generated by the Control Panel tamper should
be linked. If no area is associated, no control panel tamper alarm will be
activated. The control panel tamper can be assigned to multiple areas.
Set which area(s) the alarm generated by the siren tamper (ST) should be
linked.
Tamper alarm response mode.
Control panel tamper, siren tamper, BUS module tamper that can generate
different responses including SILENT, BUZZER, SIREN, and BUZ/SIR.