EasyManua.ls Logo

Dahua DHI-ARC3008C - Page 52

Dahua DHI-ARC3008C
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm Control Panel Installer Manual
51
Submenu
Setting
FIRMWARE VER
Show the firmware version of the Control Panel.
Press to return to the SYSTEM FUNCTIONS menu. Step 4
Then you can press and to move to the next menu or press to exit from the
Installer Menu.
SYSTEM TIMING 1.29
After entering the Installer Menu, press and to scroll up and down until you reach the Step 1
SYSTEM TIMING menu. See Figure 1-26.
System timing Figure 1-26
Press to enter the programming mode. Step 2
Configure the settings. See Table 1-23. Step 3
Press and to alter the options. Press to confirm the setting and move to the next
submenu.
The two numeric fields 000.00 represent minutes and seconds.
Table 1-23 System timing settings
Submenu
Setting
SIR AL DUR
Siren Alarm Duration.
Set the alarm lasting time of the siren.
SIR AL DLY
Siren Alarm Delay.
Set the delay time for alarm output from siren.
CHIME AL DUR
Chime Alarm Duration.
Set the activation time of the CHIME alarm.
FIRE AL DUR
Fire Alarm Duration.
Set the activation time of the FIRE alarm.
PANIC AL DUR
Panic Alarm Duration.
Set the activation time of the PANIC alarm.
HOLDUP AL DU
Hold-up/Robbery Alarm Duration.
Set the activation time of the ROBBERY alarm.
MEDICL AL DU
Medical Alarm Duration.
Set the activation time of the MEDICAL alarm.
AC LOSS DLY
AC Loss Delay.
Set the delay time for the activation of the outputs that follow a main power
loss condition.