Local Basic Operations 246
Enter the email subject.
Supports Chinese, English and Arabic numerals. It supports
maximum 64 characters.
Enable the attachment function. When there is an alarm event, the
system can attach snapshots as an attachment to the email.
Select the encryption type: NONE, SSL, or TLS.
For SMTP server, the default encryption type is TLS.
This is the interval that the system sends an email for the same
type of alarm event, which means, the system does not send an
email upon any alarm event.
This setting helps to avoid the large amount of emails caused by
frequent alarm events.
The value ranges from 0 to 3600. 0 means that there is no interval.
Enable the health test function. The system can send a test email
to check the connection.
This is the interval that the system sends a health test email.
The value ranges from 30 to 1440. 0 means that there is no
interval.
Click Test to test the email sending function. If the configuration is
correct, the receiver’s email account will receive the email.
Before testing, click Apply to save the settings.
Step 3 Click Apply to complete the settings.
4.12.7 SNMP
This function is for some series only.
You can connect the Device with some software such as MIB Builder and MG-SOFT MIB
Browser to manage and control the Device from the software.
Preparations
Install the software that can manage and control the SNMP, such as MIB Builder and
MG-SOFT MIB Browser
Obtain the MIB files that correspond to the current version from the technical support.
Configuration Steps
Step 1 Select Main Menu > NETWORK > SNMP.
The SNMP interface is displayed. See Figure 4-215.