EasyManua.ls Logo

Daihen varstroj V ARMIG 1600c Profimig - User Manual

Default Icon
34 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
N A V O D I L O Z A U P O R A B O
B E D I E N U N G S A N L E I T U N G
O P E R A T I N G I N S T R U C T I O N S
H A S Z N Á L A T I U T A S Í T Á S
U P U T S T V O Z A U P O R A B U
U P U T S T V O Z A U P O T R E B U
UPATSTVO ZA UPOTREBA
VARMIG 1905c Profimig
VARMIG 1600c Profimig
DAIHEN VARSTROJ
varjenje in rezanje ter robotizacija d.d.
Industrijska ulica 4
SLO- 9220 Lendava
Tel:
fax:
E-mail:
url:
+ 386 (0)2 5788 820
+ 386 (0)2 5751 277
info@varstroj.si
http://www.varstroj.si
Prodaja:
Export:
Servis-tel:
Servis-fax:
SLO
D
GB
H
HR
SRB
BIH
MNE
MAK
SLIKA 1, BILD 1,
FIGURE 1, ÁBRA 1,
SLIKA 1, SLIKA 1
SLIKA 2, BILD 2,
FIGURE 2, ÁBRA 2,
SLIKA 2, SLIKA 2
Art.: 604264 v.2020.12

Questions and Answers

  • M
    michelledanielsAug 14, 2025
    Why does my Daihen varstroj Welding System have poor welding properties?
    • S
      Steven MyersAug 14, 2025
      Poor welding properties in your Daihen varstroj Welding System can stem from several factors. Check the following: * Ensure correct welding parameter settings. * Verify a solid earth connection to the workpiece. * Confirm sufficient shielding gas supply, inspecting the pressure regulator, hose, solenoid valve, and torch connection. * Inspect for a leaking welding torch and replace if necessary. * Check the contact tube for wear or incorrect type and replace if needed. * Verify the wire alloy and diameter match the requirements, inspecting the wire spool. * Ensure the shielding gas is appropriate for the wire alloy being used.
  • S
    Shane HaasAug 18, 2025
    What to do if my Daihen varstroj V ARMIG 1600c Profimig has no shielding gas?
    • J
      John AllisonAug 18, 2025
      If your Daihen varstroj Welding System has no shielding gas, while other functions are working, consider these possible causes: * The gas cylinder may be empty, so replace it. * The gas pressure regulator could be faulty, requiring replacement. * The gas hose might be damaged or not properly mounted; ensure it is correctly attached or replace it. * The welding torch might be defective, so replace it. * The gas solenoid valve may be defective, requiring replacement.
  • R
    reyesgregoryAug 21, 2025
    What to do if Daihen varstroj V ARMIG 1600c Profimig Welding System doesn't work when the mains switch is on?
    • J
      Jamie RogersAug 21, 2025
      If your Daihen varstroj Welding System doesn't work when the mains switch is on, check these potential issues: * A phase failure may be occurring; inspect the mains fuse protection, mains supply lead, and mains plug. * There might be no contact between the mass clamp and the workpiece; ensure a tight connection. * The power transformer could be damaged; check or replace it. * The switch itself might be damaged; check or replace it.
  • A
    Alec RiveraAug 25, 2025
    Why is there no welding current in my Daihen varstroj V ARMIG 1600c Profimig Welding System?
    • A
      Anthony ReidAug 25, 2025
      If your Daihen varstroj Welding System shows no welding current, but the mains switch is ON and the indicators are lit, it could be due to: * A wrong earth connection. Inspect the earth connection and clamp for correct polarity. * A break in the current cable in the welding torch. Replace the torch.
  • B
    Brianna FoxAug 28, 2025
    How to fix irregular wirefeed in Daihen varstroj Welding System?
    • E
      Elaine MyersAug 28, 2025
      Irregular wirefeed in your Daihen varstroj Welding System, causing the welding wire to loop, can be resolved by: * Loosening the brake if the braking force is set too high. * Using a suitable contact tube if the current one is too narrow. * Checking the wire inner liner for kinks or dirt and ensure it is not defective. * Using suitable wirefeed rollers for the wire being used. * Optimising the contact pressure of the wirefeed rollers.
  • B
    bmcdonaldAug 31, 2025
    What to do if Daihen varstroj V ARMIG 1600c Profimig doesn't function when pressing the torch trigger?
    • Y
      Yvonne DiazAug 31, 2025
      If your Daihen varstroj Welding System does not function when the torch trigger is pressed, but the mains switch is ON and indicators are lit, it may be due to: * A defective welding torch or torch control lead. Replace the torch. * A defective or improperly connected interconnecting cable. Check the interconnecting cable.
  • J
    Justin AvilaSep 3, 2025
    Why is the arc incontinous, week or bad on my Daihen varstroj V ARMIG 1600c Profimig?
    • B
      Brett MaldonadoSep 3, 2025
      An incontinous, weak, or bad arc on your Daihen varstroj Welding System can be caused by: * Poor contact between the mass clamp and the workpiece. Clean the contact point and tighten the earthing connection. * Incorrect welding current selected. Select the appropriate welding current, referring to the operating instructions.
  • V
    Veronica GreenSep 7, 2025
    What to do if Daihen varstroj Welding System stopped welding and the temperature indicator is lit?
    • M
      melvindelgadoSep 7, 2025
      If your Daihen varstroj Welding System suddenly stopped welding, the fan is running, and the temperature indicator is lit up, it indicates over-temperature in the electric circuit. Allow the machine to cool down until the temperature indicator turns off. Do not switch off the machine while it is cooling.
  • K
    kwalkerSep 10, 2025
    Why does my Daihen varstroj V ARMIG 1600c Profimig have insufficient cooling power?
    • S
      Shane Bridges MDSep 10, 2025
      Insufficient cooling power in your Daihen varstroj Welding System may be due to: * A defective fan. Replace the fan. * Too high ambient temperature. Avoid exposing the machine to direct sunlight and prevent welding in overheated rooms.

Summary

Safety Regulations

Personal Protection and Protection of Others

Essential safety measures for operators and bystanders during welding.

Fire and Explosion Prevention

Procedures to prevent fire outbreaks and explosions during welding operations.

Metal Fume Hazards

Information on hazards from welding fumes and gases, and ventilation.

Transporting the Power Source

Description of the Machine

Intended Use

Specifies the sole intended purpose of the VARMIG welding machines.

Construction

Welding with Flux Cored Wire

Information on using the machine for welding with flux cored wire.

Configuration of the Machine

Wirefeeding Mechanism with Motor

Description of the wirefeeding motor and mechanism.

Preparing for Welding

Mains Connection

Instructions for connecting the welding machine to the power supply.

Gas Cylinder Setup

Instructions for positioning and securing the gas cylinder.

MIG;MAG Welding Procedure

Care and Maintenance

List of Spare Parts

Comprehensive list of available spare parts with figure positions.

Troubleshooting Guide

Common errors, their causes, and recommended remedies.

After-Sales Services and Warranty

Appendix: Instructions for Use

Disposal of the Device After Its Service Life

Environmental guidelines for proper disposal of the appliance.

RoHS Compliance

Declaration of compliance with the RoHS Directive.

Daihen varstroj V ARMIG 1600c Profimig Specifications